background image

- 6 -

M965560  Rev. 1.3 (5/17) 

• Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled as 

“Cam” in the illustration. 

Fig. B.

•  Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the 

Stopper should be in the UP position. 

Fig. B, C. 

• Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig. C.

•  Re-attach the Cable to the Drain Body Connection

 (2)

 by threading the Cable Connector 

(1)

 clockwise onto the 

Drain Body Connection 

(2)

 and hand-tighten. 

Fig. A.

• Disconnect the Cable from the Drain by threading the Cable Connector

 (1)

 counter-clockwise. 

Fig. A.

•  Look at the area on the Drain Body where the Cable was attached and locate the component labeled 

as “Cam”  and “Cam Cap” in the illustration. 

Fig. B.

• Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain.

 Fig. D.

• Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig. E.

• The Stopper can now be removed by lifting it out of the Drain. 

Fig. F.

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

     • Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.                                                                       

CABLE ADJUSTMENT PROCEDURE

STOPPER REMOVAL PROCEDURE

Speed Connect

®

 Drain

Troubleshooting Guide

REMOVE

CAM

Fig.

 

E.

Fig.

 

F.

Fig.

 

D.

REMOVE

CAM CAP

CAM

CAM CAP

Fig.

 

B.

Fig.

 

A.

2

1

RE-ATTACH

DISCONNECT

Fig.

 

C.

DOWN

STOPPER

REMOVE

CAM

Fig.

 

E.

Fig.

 

F.

Fig.

 

D.

REMOVE

CAM CAP

CAM

CAM CAP

Fig.

 

B.

Fig.

 

A.

2

1

RE-ATTACH

DISCONNECT

Fig.

 

C.

DOWN

STOPPER

Summary of Contents for Randall D35102100

Page 1: ...MOUNTING HOLE 1 3 8 DIA 35 mm 12 5 16 316 mm 4 1 8 105 mm 8 1 8 206 mm 3 1 16 DIA 77 mm 6 152 mm MTG SURFACE 24 610 mm 2 1 16 MAX 53 mm 12 MAX 305 mm MAX 2 51 mm 1 1 4 O D 32 mm 3 8 32 mm SUPPLIES Flat Blade Screwdriver Plumber s Putty or Caulking Adjustable Wrench Tubing Cutter Channel Locks In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer ...

Page 2: ...INING WASHER 4 and LOCKNUT 6 onto faucet SHANK 3 Before final tightening faucet should be seated flush on mounting surface Adjust faucet so that it is centered and covers mounting hole Tighten LOCKNUT 6 using a 15mm or adjustable wrench Do not over tighten Installation is the same for VESSEL FAUCET 8 INSTALL FAUCET LAVATORY AND VESSEL FAUCETS CAUTION Turn off hot and cold water supplies before beg...

Page 3: ... against LOCKNUT 3 Fig B From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible ...

Page 4: ... to the troubleshooting section of these instructions Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 10 mm compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 24 610 mm long from faucet base Note If additional supply length is required installer must purchase additional parts sepa...

Page 5: ...ections for leaks Remove AERATOR 3 Operate HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in sink If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain c...

Page 6: ...ap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROCEDURE ...

Page 7: ...USTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate Sto...

Page 8: ...iate finish code POLISHED CHROME 100 BRUSHED NICKEL 144 PLATINUM NICKEL 150 M952425 XXX DRAIN ASSEMBLY A860811 XXX HANDLE ASSEMBLY M964732 YYY0A LIFT KNOB ROD M952430 0070A SPPED CONNECT ASSEMBLY Vessel Faucet M964733 YYY0A CAP AND NUT M964507 0070A MOUNTING KIT M964737 YYY0A AERATOR ASSEMBLY M964736 YYY0A ROSETTE A860621 191 CARTRIDGE ASSEMBLY Lavatory Faucet ...

Reviews: