background image

(1) IR CONNECTING BOX   
Features and Characteristics 

 

Four IR emitter output connections for 4 single/ dual emitters. 

 

Two IR receiver inputs – 1x 3.5mm jack and 1x 3-p screw terminal block. 

 

Power socket with LED indicator to show on/off status. 

 

Adhesive tape for mounting near audio equipment.

 

 
Installation 

Power:   

Connect a 12V DC 550mA power adapter to the power jack of the Connecting 
Box.    The green LED will be illuminated when powered.    This will power all of 

the IR components connected to the system. 

IR system connection: 

Connect the IR system to the detachable terminal connector printed thus: V+ 

(12VDC), G(Ground), and IR (Signal).    Or use a 3.5mm jack for the other IR 
socket on the Connecting Box. 

Emitter Outputs:

   

Choose the most suitable parts for your application such as single emitters 

(supplied) or dual IR emitters (optional accessory).    Connect up to four emitters

 

to the emitter jacks marked 1-4 in the Connecting Box.    Place the emitters 

directly onto the source equipment’s IR sensors (up to 4 units when using the 
single emitters, up to 8 when using dual emitters). 

Mounting:   

Mount the Connecting Box near the source equipment to which the emitters are 
attached. 
 

 

(2) DUAL-BAND IR RECEIVER - 

SPECIFICATION & FEATURES: 

 

Carrier Frequency: 38kHz + 2kHz and 56kHz + 2kHz. 

 

Control Range: 38kHz up to 15 meters and 56kHz up to 10 meters indoors on 

axis, depending on remote transmitter signal strength and ambient 

interference.    Direct sunlight can reduce the range of the IR signal. 

 

Reception Angle: Up to 6 meters distance for + / – 45 degrees off axis. 

 

LED display: 

Activity LED: When IR signal is received from the remote control, the red LED 
indicates IR activity. 

Status LED: The Blue LED for System On/Off indication. 

 

IR Lens: Limits visible light interference. 

 

Room to Room wire recommendation: Using 3-conductor (min.) 24 gauge 

unshielded solid or stranded copper wire up to 300 meters length. 

 

Power Requirement: 12Vd.c., (500~1200mA), using a regulated adaptor is 

always recommended. 

 

Dimension: 32(L) x 13(W) x 12(H) mm. 

 
 

(3) IR EMITTERS – Single or Dual 

SPECIFICATION and FEATURES:

 

 

Infrared emitter is built into transparent housing. 

 

Non-blinking version with peak wavelength 940nm. 

 

Cable length = 3m. 

 

Uses 3.5mm standard mono plug. 

 

Self-adhesive tape provides quick and easy fixing to any hard, clean, and dry 

surface. 

NOTES:

 

 

Make sure mounting surface must be clean and dry for well fixing. 

 

Do not connect the IR emitter directly to any power supply or battery. 

 

 

(4) POWER ADAPTER - 12V/500mA Switching mode 

 

This is a 12Vd.c. 500mA power supply for powering IR components. Power 

connectors: Diameter 2.1mm, Tip positive, sleeve negative. 

 

 

2.

 

CODES COMPATIBILITY:

 

   

NEC Code 

◆◆

 

Sharp Code 

◆◆

 

RC5 Code 

◆◆

 

Sony 12-bit Code 

◆◆

 

RC6 Code 

◆◆

 

Sony 15-bit Code 

◆◆

 

RCMM Code 

◆◆

 

Sony 20-bit Code 

◆◆

 

r-step code 

◆◆

 

Zenith Code 

◆◆

 

RCS-80 Code 

◆◆

 

High Data Rate Code 

◆◆

 

R-2000 Code 

◆◆

 

Disturbance Suppression 

◆◆

 

RCA Code 

◆◆

 

XMP code 

◆◆

 

3.

 

NOTE: 

◆◆ Best for this application 

 