background image

D18XX Series PoE Midspan 4 to 16 ports - Installation Manual - D18XX-INST /11E/v1                                           Page 2 of 6 

 

 

 

1 Package 

Contents 

D18XX PoE Mid-span unit 

- Mains 

cable 

Four M4 x 8mm Philips flat head screws 

- Dycon 

warranty 

statement 

- D1800 

series 

manual 

2 Description 

The D1800 PoE Midspan Series is powered by one or more highly efficient switched mode power 
supplies that reduce rack cabinet heat and user running costs.  The unit is designed for simplicity and 
true “Plug and Play” system integration.  The unit will simultaneously supply over 30 watts to each 
connected powered device and individual ports are over-current protected according to the class of 
the connected device. 

2.1 Features 

 

IEEE 802-af and IEEE 802-at Type 1 and Type 2 compliant

 

 

Power supply better than 85% efficient at full load

 

  Genuine full power available simultaneously across all ports 

 

Fully automatic powered device signature detection and power limiting

 

 

4 to 16 port model variants available

 

 

3U 19 inch rack mounted and desk mounted versions

 

  Simple “Plug and Play” system integration 

  Full thermal and over-current protection 

  Power outputs transient protected 

  Power supply failure redundancy limited to multiples of 4 ports   

3 Installation 

 

D1804 – 4 ports – front plate 

 

D1808 – 8 ports – front plate 

All manuals and user guides at all-guides.com

Summary of Contents for d1800 Series

Page 1: ...wer PoE Midspan Power Supply Dycon Ltd Tel 44 0 1443 471 060 Fax 44 0 1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER UK www dyconsecurity com info dyconsecurity com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...d powered device and individual ports are over current protected according to the class of the connected device 2 1 Features IEEE 802 af and IEEE 802 at Type 1 and Type 2 compliant Power supply better than 85 efficient at full load Genuine full power available simultaneously across all ports Fully automatic powered device signature detection and power limiting 4 to 16 port model variants available...

Page 3: ...rs and the output with injected power is connected to the corresponding upper data and power output connector 1 Check the unit is plugged in and switched on at the rear of the unit The yellow standby LEDs on the front modular connectors will be illuminated indicating that power is available 2 Connect the Ethernet data cables to the bottom row data inputs 3 Connect the cable to the powered device t...

Page 4: ...40 C Size L x W x D 485mm x 285mm x 90mm Weight 4kg 4 3kg 4 6kg 4 9kg 5 Safety and environmental Information 5 1 Equipment Modifications This equipment must be installed and used in strict accordance with the instructions given in this manual This equipment contains no user serviceable components Unauthorised changes or modifications to this equipment will invalidate all applicable regulatory cert...

Page 5: ...Peru IT equipment cannot power this device In the case of an IT powered device the unit needs to be powered by 230V through an isolation transformer with a ratio of 1 1 and the secondary connection Neutral is properly grounded 5 3 Precautions Please read the following carefully before installing and connecting the system to a power source 1 Only qualified and trained service personnel in accordanc...

Page 6: ...trical and Electronic Equipment directive 5 6 Electromagnetic Compatibility EMC This digital equipment fulfils the requirements for radiated emission according to limit B of EN55022 1998 and the requirements for immunity according to EN55024 1998 residential commercial and light industry 6 Support Trouble shooting In case you require any technical assistance please contact Dycon Technical Support ...