5.2 Power Cord Requirements
Power cords must meet the requirements for the country they are used in.
-
The Dycon PoE Midspan must have access to a power outlet. Disconnect the power cord
from the outlet, to eliminate power from the device.
-
The flexible cord that connects to the Dycon PoE Midspan must have a configuration to
connect with an EN60320/IEC320 inlet connector.
-
According to the EN60950/IEC 950 specifications, this device functions under Safety Extra
Low Voltage (SELV) conditions. The conditions are true if the equipment and the connected
device function under SELV conditions.
-
The Dycon PoE Midspans meet EN60950 safety standards (displayed in the back of the
product).
Europe and South America
Switzerland
The supply plug must comply with SEV/ASE 1011.
Denmark
The supply plug must comply with section 107-2-D1, standard DK2-1a or
DK2-5a.
United Kingdom
The Dycon PoE Midspan is covered by General Approval (section 1.16.060),
NS/G/12345/J100003, for indirect connection to a public telecommunication
system.
France/Peru
IT equipment cannot power this device. In the case of an IT-powered
device, the unit needs to be powered by 230V through an isolation
transformer with a ratio of 1:1 and the secondary connection (Neutral) is
properly
grounded.
5.3 Precautions
Please read the following carefully before installing and connecting the system to a power source.
1. Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS
3260) should install, replace, or service the equipment. Install the system in accordance
with country or national codes.
2. The building where this product is used, requires a fuse or circuit breaker no larger than 10A,
230 VAC. The building facility must protect the Dycon PoE Midspan from over-current or
short-circuits.
3. Read the Hardware Setup procedure before connecting the Dycon PoE Midspan to a power
source (this includes power cord requirements).
4. Do not operate the product in an area that exceeds the maximum recommended ambient
temperature of 40°C to avoid overheating the Dycon PoE Midspan. Allow at least between
7.5 and 10.5cm clearance around all ventilation openings.
5. Do not stack the chassis on any other equipment to support its weight. Shelf-mounted
equipment requires a stable and durable surface. Do not push or pull on the Dycon PoE
Midspan while installing.
6. The Dycon PoE Midspan consists of two (2) rows of “Data” and “Data and Power” ports.
The ports use 8P8C modular data sockets.
7. Connect only 8P8C modular cables to these sockets: do not connect telephone cables in
these ports.
8. Do not work on the Dycon PoE Midspan equipment, connect or disconnect cables when
there is lightning.