Dymax BlueWave® LED Prime UVA User Guide
used to verify step or ramped changes in the intensity for customized profiles, or to alert the remote
controller when the system has reached maximum intensity in a closed-loop system.
Pin 9
–
Over Temp Out:
A sensor constantly monitors the temperature of the LED in the system. If, for any
reason, the reading rises above a predetermined limit, the control PCB will shut off current to the LED to
prevent damage. When the measured temperature drops to a lower threshold, the PCB will re-enable current
to the LED.
NOTE: If this fault occurs check for proper airflow into and out of the unit. Also verify that the air filter is clean.
Figure 9. 9-Pin D Connector I/O Signals
Cleaning and Maintenance
The
BlueWave LED Prime UVA
was designed to operate with minimum maintenance. Follow the schedule
below to assure top unit performance.
Lightguide
Clean the lightguide ends monthly or as required. The ends of the lightguide should be kept clean to transmit
as much light as possible. Cured adhesive can carefully be removed from liquid-filled lightguide ends with a