BlueWave® MX-250 Emitter User Guide
6
Unpacking
Upon arrival, inspect all boxes for damage and notify the shipper of box damage immediately.
Open each box and check for equipment damage. If parts are damaged, notify the shipper and
submit a claim for the damaged parts. Contact Dymax so that new parts can be shipped to you
immediately.
WARNING!
Until the BlueWave® MX-250 emitter is attached to a controller
via the interconnect cable it is susceptible to ESD damage, handle according to ESD
standards using a ground strap and do not touch exposed connector pins.
The parts below are included in every package/order. If parts are missing from your order,
contact your local Dymax representative or Dymax Customer Support to resolve the problem.
Parts Included
▪
BlueWave® MX-250 LED Emitter Assembly
▪
User Guide
Installation
The BlueWave® MX-250 emitter is part of a MX-series curing system and requires connection
to a controller via an interconnect cable for proper operation.
Important Information
▪
Do not connect any components while power is applied.
▪
Mount the BlueWave® MX-250 emitter to a rigid support, such as the emitter
stand PN 42390, prior to connecting the interconnect cable to prevent handling
damage.
▪
Do not touch the emitter aperture glass. This can result in poor performance
and broken glass due to heating. Inspect before each use and clean with
isopropyl alcohol if contaminated.
▪
If emitter aperture glass is permanently contaminated it must be replaced for
safe operation.