26
Dymax SG-200 High-Flow Spray Gun System User Guide
4.
Adjust the pressure on the air regulator feeding the valve handle to 80 psi.
Figure 13. Air Filter/Regulator with Quick Air-Shutoff Lever (PN T16307)
5.
Depress the trigger on the handle (Figure 14) to cycle the valve open and closed. You should hear the
solenoid actuating inside the handle and will be able to see the center needle of the spray valve moving
back and forth.
WARNING!
Do not look directly into the spray gun. Always view needle position from the side.
Figure 14. Spray Gun Handle
6.
Adjust the pressure on the atomizing air regulator (
Figure 12) between 2-3 psi (0.14
–
0.21 bar) for startup.
NOTE:
This pressure setting will only show when the trigger of the handle (Figure 14) is pressed.
8.
To begin the flow of material to the valve, take the necessary step(s) to pressurize the pressure vessel the
material is in. Adjust the precision air regulator to achieve the desired material flow rate.
Supply Inlet: 0.25" nptf
Outlet: 0.25" OD push-in fitting
Trigger
Quick Air-Shutoff Lever