29
Dymax SG-200 High-Flow Spray Gun System User Guide
Cleaning and Maintenance
NOTE:
Numbers noted in this section refer to part callouts in Figure 11.
Figure 16. Valve Parts Breakdown
Periodic Maintenance
Maintain the air filter/regulator in accordance with the supplied OEM instructions.
Maintain the air precision regulator in accordance with the supplied OEM instructions.
Lubricate the packing (5) on the valve every 200 hours by placing a few drops of mineral oil or other light oil
inside the packing nut.
The packing nut will require occasional tightening, as wear occurs to prevent leaks through the packing.
System Cleaning
Switching to a Different Fluid
To switch your system over from dispensing one fluid to dispensing a new fluid, determine if the fluids are
compatible with pump and valve components. If you are uncertain about material compatibility, contact
Dymax Application Engineering for assistance. If the fluids are compatible, replace the fluid tubing and clean
the dispensing valve and spray cap.
Follow Setup Section for all new materials to set RAM pump, material regulator, and atomizing pressures.
Routine Cleaning and Disassembly
Cleaning and rebuilding the valve will be required from time to time. Follow the instructions below to properly
do so.