16
Dymax SG-200 High-Flow Spray Gun System User Guide
Connecting the DVC-345 Controller
1.
Locate a convenient, clean position to place the controller.
NOTE:
If using a spray booth or environment where electrical devices are forbidden, position the controller
outside of the immediate environment.
2.
Connect the power supply to 345 Controller.
3.
Connect the t
ubing from the Spray Gun to the “A” and “B” Outlets located on the back of the Controller.
The red tubing connects to Port A. The blue tubing connects to Port B. (Figure 7)
4.
Connect the ¼" jack from the spray gun to the External Trigger Jack located on the back of the 345
controller.
5.
Connect the DVC-345 Controller Air In Port on the rear panel to the control valves.
Figure 7. DVC-345 Connections
6.
Turn the Controller to untimed mode for manual use. For timed shot applications, program the controller
appropriately. Instructions can be found in MAN028
–
DVC-345 Valve Controller User Guide.
7.
Test the valve actuation by depressing the trigger on the spray gun. If the gun is not working properly,
check the air line connections and controller settings.
WARNING!
Always aim the spray nozzle away from yourself and others to reduce risk of accident or
injury.