17
OPERATION INSTRUCTIONS
LIGHTING INSTRUCTIONS
CAUTION: If the flame extinguishes accidentally during ignition or operation,
immediately TURN OFF the cylinder valve and then TURN OFF the control knob.
Igniter Lighting System
1. Check all connections for leaks using the “soap water” test as explained on page 15
for “checking for leaks.”
2. Open both of the smoker cabinet doors. Always keep the doors open during lighting.
3. Check for any blockage to the venturi tube or burner, damper setting, ventilation setting.
Remove any foreign objects or matter.
4. Be sure the burner control knob is in the
“OFF”
O
position.
5. Open the LP cylinder valve by turning
counterclockwise .
6. Push igniter on the control unit down 1 to
2 seconds then push and turn control knob to
“HIGH” , while still holding the ignitor button
down. At this point the burner should ignite.
7. If ignition does not take place within 5 seconds, immediately turn the control knob to OFF
O
.
Wait 5 minutes and repeat above steps 6 and 7.
8. If burner still fails to light, try match lighting using the instructions on page 18.
9. Once the burner is lit, close the doors to allow heat to accumulate. The smoke stack
on the top of the smoker can be adjusted to the desired setting to allow proper ventilation
and combustion. NEVER CLOSE THE SMOKE STACK COMPLETELY.
Warning: Always light your smoker with both doors open.