IMPORTANT SAFETY INSTRUCTIONS

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water.

6.

Clean only with a dry cloth.

7.

Do not cover any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.

Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.

Do not defeat the safety purpose of the polarized or the grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician
for replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.

Only use attachments/accessories specified by the manufacturer.

12.

Use only with the cart, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving
the cart/apparatus combination to avoid injury from tip-over.

13.

Unplug this apparatus during lightning storms or when unused for a long period of time.

14.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or orbjects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate
normally, or has been dropped.

15.

Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

16.

To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

17.

The mains plug of the power supply cord shall remain readily operable.

18.

No naked flame sources, such as lighted candles, should be placed on the apparatus.

19.

The product should be connected to a mains socket outlet with a protective earthing connection.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not

perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer

all servicing to qualified service personnel.

1.

Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.

Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.

Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.

The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and
needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains
(secondary parts) has to be 6 mm and needs to be minded at all times.

5.

Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.

Altering the circuitry without prior consent or advice is not legitimate.

7.

Any work security regulations that are applicable at the locations where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations
about the work place itself.

8.

All instructions concerning the handling of MOS-circuits have to be observed.

Speakon is a registered trademark of Neutrik AG

The lightning flash with arrowhead symbol, within an equilateral
triangle is intended to alert the user to the presence of uninsulated
”dangerous voltage” within the product’s enclosure that may be of
sufficent magnitude to constitute a risk of electric shock to per-
sons.

The exclamation point within an equilateral triangle is intended to
alert the user to the presence of important operating and
maintance (servicing) instructions in the literature accompanying
the appliance.

NOTE:

SAFETY COMPONENT (MUST BE REPLACED BY ORIGINAL PART)

Summary of Contents for PSD 215

Page 1: ...PSD 215 218 POWERED SUBWOOFER Owner s Manual Bedienungsanleitung ...

Page 2: ...PSD 215 218 2 ...

Page 3: ...ode 8 Power amplifer and cooling 12 Quickstart 12 SPECIFICATIONS 24 Block Diagram 25 Dimensions 26 Setup Examples 27 INHALT EINFÜHRUNG 15 Lieferumfang Auspacken und Überprüfen 15 Garantie 15 INSTALLATION 16 Bedienelemente Anzeigen und Anschlüsse 16 Menü 18 Leistungsverstärker und Kühlung 22 Quickstart 23 SPECIFICATIONS 24 Block Diagram 25 Dimensions 26 Setup Examples 27 ...

Page 4: ... the apparatus 19 The product should be connected to a mains socket outlet with a protective earthing connection IMPORTANT SERVICE INSTRUCTIONS CAUTION These servicing instructions are for use by qualified personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so Refer all servicing to ...

Page 5: ... also the level can be edited by the us er The System EQ allows adjustments to be made for the acoustics of the room The DSP Out also offers an adjust able delay high pass and shelving equalizer as well as a level control It is therefore ideally adapted among other things to the use of an active delay box Signal generators with sine pink noise or spike pulses are integrated to facil itate tuning t...

Page 6: ...EME CARE WHEN SETTING SOUND PRESSURE LEVELS WARNING AVIS THIS CLASS B DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES 003 CET APPAREIL NUMÉRIQUE DE LA CLASSE B EST CONFORME À LA NORME NMB 003 DU CANADA SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO REDUCE THE RISK OF FIRE OR ELECTRIC LIMIT ON RISQUÉ DE CHOC ELECTRIQUE NE PAS OUVRIR 10 8 7 5 4 9 11 2 6 3 1 12 13 Number Description 1 Mains ...

Page 7: ...n be utilized for feeding the digitally processed audio signal from the PSD to additional powe red speakers or amplifiers without DSP mo dule Use the DSP OUT Settings dialog see page 10 in the menu for configuring the output signal The output si gnal is electronically balanced with a maximum level of 15 dBu Output impedance is 150 ohms 7 OUTPUT CONNECTOR THRU The output connector provides the INPU...

Page 8: ...he left or to the right to move the cursor in the menu Press the MENU ENTER rota ry encoder to select or execute the highlighted menu item If a menu entry was highlighted the corresponding dialog is opened If a parameter was highlighted the value is shown in inverse font and can be edited by turning the MENU ENTER rotary encoder Press the MENU ENTER rotary encoder again to apply the edited paramet...

Page 9: ...TEM ALIGNMENT This dialog allows to set up the basic speaker settings of the PSD system Turn the MENU ENTER rotary encoder to highlight an entry in the left column of the System Alignment dialog Press the MENU ENTER rotary encoder to select the corresponding value in the right column Now turn the MENU ENTER rotary encoder to edit the value and press the MENU ENTER rotary encoder again to apply the...

Page 10: ...UTPUT and the EXTERNAL SUB OUTPUT The preferred delay unit can be selected in the Device Setup dialog see page 11 SUB Delay This parameter allows timing adjustment of loudspeakers dri ven by the PSD amplifier e g alignment of top speaker and subwoofer Enter a positive value e g 50cm if the PSD is closer to the audience than the top speaker in this case the subwoofer signal is delayed Enter a negat...

Page 11: ... be locked after entering the PIN see Lock Device dialog Table 2 14 lists the dialogs or parameters that will be locked for the available lock levels HINT The SUB Level parameter is never locked so mut ing or adjusting the volume of the PSD is always possible Factory Reset The PSD can be reset to factory settings Pressing the MENU ENTER rotary encoder opens a Also clear User Mem dialog box that le...

Page 12: ...he connector into the MAINS IN socket Use the Mains switch to power ON the PSD the ON LED lights green 5 After the first power on of the PSD 215 the Preset Select dialog automatically appears in the display to open the dialog manually press the PRESET function key 6 Select the TS 400 preset from the preset list by turning the MENU ENTER rotary encoder 7 Press the MENU ENTER rotary encoder to load ...

Page 13: ...PSD 215 218 13 ...

Page 14: ...rät 16 Um das Gerät komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden 17 Beim Einbau des Gerätes ist zu beachten dass der Netzstecker leicht zugänglich bleibt 18 Stellen Sie keine offenen Brandquellen wie z B brennende Kerzen auf das Gerät 19 Dieses SCHUTZKLASSE I Gerät muss an eine NETZ Steckdose mit Schutzleiter Anschluss angeschlossen werden WICHTIGE SERVICEHINWEISE ACHTUNG...

Page 15: ...des Gerätes werden die Leistungsausgänge verzögert zugeschaltet um eventuelle Störgeräusche zu vermeiden Die thermische Stabilität wird durch einen stufenlos ge regelten Lüfter mit sehr niedrigem Geräuschpegel gewähr leistet Außerdem verfügen die Endstufenkanäle über einen intelligenten Thermo Limiter im Falle einer dro henden Überhitzung werden lediglich die Leistungsspitzen durch einen musikalis...

Page 16: ...G USE EXTREME CARE WHEN SETTING SOUND PRESSURE LEVELS WARNING AVIS THIS CLASS B DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES 003 CET APPAREIL NUMÉRIQUE DE LA CLASSE B EST CONFORME À LA NORME NMB 003 DU CANADA SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE TO REDUCE THE RISK OF FIRE OR ELECTRIC LIMIT ON RISQUÉ DE CHOC ELECTRIQUE NE PAS OUVRIR 10 8 7 5 4 9 11 2 6 3 1 12 13 Nummer Beschreibu...

Page 17: ...VICE Dieser Anschluss ist für zukünftige Funk tionen vorgesehen 6 AUSGANG FÜR DSP AUSGANGSSIGNAL DSP OUT An der XLR Buchse DSP OUT liegt ein vom digitalen Signalprocessing verarbeitetes Si gnal an Der Ausgang DSP OUT kann ver wendet werden um weitere Endstufen ohne DSP Modul oder aktive Lautsprecher mit einem Line Signal aus dem PSD zu versorgen Zur Anpassung des Signals verwenden Sie den DSP OUT ...

Page 18: ...rmenüs werden der MENU ENTER Drehencoder und die vier Funktionstasten unter dem Display für die Navigation Auswahl und Parameteränderung verwendet Durch Drehen des MENU ENTER Drehencoders kann die Markierung im Display be wegt werden Durch Drücken des MENU ENTER Drehenco ders wird der markierte Eintrag ausgeführt bzw ausgewählt Handelt es sich um einen Menü Eintrag wird das entsprechende Untermenü...

Page 19: ...ame Dialog kann die Bezeichung des User Memory eingegeben werden Drehen Sie den MENU EN TER Drehencoder nach links oder rechts um das mit dem Cursor markierte Zeichen zu ändern Drücken des MENU Abbildung 2 5 Menüstruktur des PSD SUB Delay SUB Polarity Generator System Alignment Testsignal SYS Level Display Brightness Factory Reset Firmware Info Device Setup Delay Unit Display Auto Dim Level Lo EQ ...

Page 20: ...passt Erneutes Drücken des MENU ENTER Drehencoders führt in die linke Spalte zurück Folgende Tabelle erläutert die Einträge des DSP OUT Settings Dialog bitte beachten Sie hierzu auch das Blockdiagramm auf Seite 25 Drücken der Funktionstaste OK führt in das Menü zurück Drücken der Funktionstaste RESET setzt die Abbildung 2 9 System Equalizer Abbildung 2 10 System Alignment System Equalizer 80 160 3...

Page 21: ...R Drehencoder nach rechts um die Zeit bis zur Abdunklung zu verlängern Drücken des MENU ENTER Drehencoder übernimmt die gewählte Einstellung Drü kken der Funktionstaste BACK führt in das Menü zurück Delay Unit Über den Eintrag Delay Unit kann die gewünschte Maß einheit Meter Feet Millisec oder Samples der Verzö gerungen im System Alignment Dialog und DSP OUT Settings Dialog gewählt werden Drehen S...

Page 22: ...tarke Endstufe in mo derner hocheffizienter Class D Technologie Es wird also nur eine vergleichsweise geringe Verlustwärme im Gerät erzeugt Wird die zulässige Betriebstemperatur der End stufe dennoch überschritten schaltet die integrierte Tem peraturüberwachung das Modul ab Sobald die Temperatur wieder im normalen Betriebsbereich liegt geht die Endstufe automatisch wieder in Betrieb Zur Abschal tu...

Page 23: ...er um das Preset zu laden 8 Verlassen Sie den Preset Select Dialog durch Drü kken der Funktionstaste BACK 9 Wiederholen Sie die Schritte 5 bis 8 am zweiten PSD 215 10 Schließen Sie nun eine Audio Quelle z B einen CD Player an einen LINE Kanal Ihres Mischpultes an Justieren Sie den Gain Regler des Eingangskanals des Mischpults so dass die Peak LED im Kanal nicht oder nur gelegentlich aufleuchtet 11...

Page 24: ...olled Output Level max before clip 15 dBu Output Impedance balanced 150 Ohms Presets 20 factory presets 5 user memories Digital Signal Processing 24 Bit 48 kHz Display 128 x 64 pixels OLED Power Requirement 100 to 240 V AC 50 to 60 Hz 5 2 to 2 7 A Safety Class I Operating Temperature Range 0 C to 40 C Protection Amplifier Audio Limiters High Temperature DC HF Short Circuit Peak Current Limiters Tu...

Page 25: ...PSD 215 218 25 3 1 Block Diagram Illustration 3 1 Frequency response of PSD 215 left and PSD 218 right ...

Page 26: ...PSD 215 218 26 3 2 Dimensions PSD 215 PSD 218 11 39 289 3mm 9 26 235 2mm 12 32 313mm 25 20 640mm 23 57 598 6mm 27 32 694mm 18 03 458mm 18 3 465mm 18 00 457 2mm 20 87 530mm ...

Page 27: ...HMS LIMIT ON PROTECT PARAMETER MENU ENTER MAINS IN ON OFF PSD POWERED SYSTEM SUBWOOFER 3200 W MAXIMUM AMPLIFIER OUTPUT CAPABILITY INPUT THRU SERVICE DSP OUT OUTPUT WIRING CLASS 2 TOP SPEAKER OUTPUT EXTERNAL SUB OUTPUT MIN LOAD IMPEDANCE 8 OHMS MIN LOAD IMPEDANCE 4 OHMS LIMIT ON INPUT THRU SERVICE DSP OUT OUTPUT WIRING CLASS 2 TOP SPEAKER OUTPUT EXTERNAL SUB OUTPUT MIN LOAD IMPEDANCE 8 OHMS MIN LOA...

Page 28: ... LIMIT ON PROTECT PARAMETER MENU ENTER MAINS IN ON OFF PSD POWERED SYSTEM SUBWOOFER 3200 W MAXIMUM AMPLIFIER OUTPUT CAPABILITY INPUT THRU SERVICE DSP OUT OUTPUT WIRING CLASS 2 TOP SPEAKER OUTPUT EXTERNAL SUB OUTPUT MIN LOAD IMPEDANCE 8 OHMS MIN LOAD IMPEDANCE 4 OHMS LIMIT ON PSD 215 218 PSE 215 218 INPUT THRU SERVICE DSP OUT OUTPUT WIRING CLASS 2 TOP SPEAKER OUTPUT EXTERNAL SUB OUTPUT MIN LOAD IMP...

Page 29: ...CT PARAMETER MENU ENTER MAINS IN ON OFF PSD POWERED SYSTEM SUBWOOFER 3200 W MAXIMUM AMPLIFIER OUTPUT CAPABILITY INPUT THRU SERVICE DSP OUT OUTPUT WIRING CLASS 2 TOP SPEAKER OUTPUT EXTERNAL SUB OUTPUT MIN LOAD IMPEDANCE 8 OHMS MIN LOAD IMPEDANCE 4 OHMS LIMIT ON PROTECT PARAMETER MENU ENTER MAINS IN ON OFF PSD POWERED SYSTEM SUBWOOFER 3200 W MAXIMUM AMPLIFIER OUTPUT CAPABILITY INPUT THRU SERVICE DSP...

Page 30: ...PSD 215 218 30 Notes ...

Page 31: ...PSD 215 218 31 ...

Page 32: ...2 844 4051 Fax 1 952 884 0043 49 9421 706 0 Fax 49 9421 706 265 Asia Pacific only For customer orders contact Customer Service at www dynacord com 65 6571 2534 Fax 65 6571 2699 For technical assistance contact Technical Support at 49 9421 706 0 Bosch Communications Systems 06 2012 PartNumberF01U247988 Vs02 Specifications subject to change without notice ...

Reviews: