Faults, Cause and Remedy
7 — 1
APS06_010_0404GB
7
Fauls, Cause and Remedy
This chapter gives you a summary of faults and their possible
causes, and also ways in which you may rectify them.
Observe the safety regulations when searching for a fault.
Only suitably trained technicians may work on the electrical system.
The Dynajet 350 mg Plus high−pressure cleaner (with the other
Dynajets mg optional) is fitted with an operating module. Any faults
relating to the assigned parameters are displayed here.
If a switch changes status during operation, the motor is stopped
after 3 seconds. The time of faults < 3 seconds is added up and
stored.
If the stored value exceeds 3 seconds, the motor is also stopped.
If a fault does not occur again within 10 seconds, the memory is
deleted. The fault that occurs first is stored and all other inputs are
locked so that you can easily determine which fault originally caused
the machine to switch off, even if the input has reverted back to its
normal status in the meantime.
Note
Input monitoring begins 7 seconds after the machine starts up in
order to give the motor a chance to build up oil pressure and charge
voltage.
7.1
High-pressure cleaner
with operating module