Pilot Operating Handbook
H3 Sport 135 HP
SECTION 2
LIMITS IN USE
Dynali_POH_H3 Sport 135 HP Rev. 3.3 – Issue date 15.01.2021 Page
28
BATT
Both switches ON/OFF ensure the activation of the batteries: ECU (1) and rest of
equipment (starter included) (2).
IGN
Both switches ON/OFF enable the activation of both electronic engine ignitions.
ALARM BUZZER
Is expressed with a light and a tone. It is activated under the following circumstances :
-
If collective > 2 % and rotor < 520 RPM;
-
If collective > 5 % ; T
oil
< 50 °C and engine ON ;
-
If collective > 5 % ; P
oil
< 2 bar and engine ON ;
-
If try to start the engine while the first fuel pump is OFF.
GOV
The indicator is orange if the governor is not active.
The indicator is flashing red if the governor is preactivated.
The indicator is blue if the governor is active.
CHIP Main (BTP) and Rear (BTA)
Indicators are green if there is no chip in the transmission gearbox and red if some is
detected.
FRAME Main and Engine
The indicator is green if the frame pressure is > 2.5 bar.
The indicator is flashing red/orange if the frame pressure < 2.5 bar.
FUEL
The indicator is green if > 15 L remains in the fuel tank.
The indicator is yellow if < 15 L remains in the fuel tank.
OIL-P
The indicator is green if the engine oil pressure is > 1 bar.
The indicator is red if the engine oil pressure is < 1 bar.
Summary of Contents for H3 Sport 135 HP
Page 85: ......