The illustrations below depict typical installations of the Model #2511 Lock on single-outswing doors. The lock
assembly must be surface mounted to the underside of the frame header with the armature affixed to the inside
face of the door as shown.
DynaLock Corp.
Electric Security Hardware
705 Emmett Street P.O. Box 9470 Forestville, CT 06011-9470 Phone (860)582-4761 Fax (860)585-0338
MOUNTING INSTRUCTIONS
SERIES 2511 ELECTROMAGNETIC LOCK
FOR A SINGLE OUTSWING DOOR
PLEASE READ BEFORE INSTALLATION
.
Familiarize yourself with the door and frame conditions prior to installation. The lock must rigidly mount to the
underside of the frame header. The armature is designed to pivot slightly to compensate for reasonable
misalignment.
Armature mounting hardware is supplied for a standard 1-3/4" thick door. For thicker doors order the following
special armature hardware kits:
Part #300687 for 2" thick doors.
Part #300688 for 2-1/4" thick doors.
HANDLING
MAINTENANCE
The Electromagnetic lock and armature are
ruggedly constructed and designed to provide
years of trouble-free service. Care must be taken
during installation and use to keep the lock face
and armature face free from dirt, rust, burrs, paint,
or any other obstruction which may interfere with
the lock and armature making good contact.
The lock assembly and door armature have been
plated for maximum corrosion resistance. To
ensure peak performance clean the lock and
armature faces with a mild detergent and a clean,
soft cloth, then apply a light coat of WD40 to protect
these surfaces. This need only be done when dirt
build-up is noticed.
page 1
GENERAL MOUNTING INFORMATION
LHRB DOOR
RHRB DOOR
LOCK
ASSEMBLY
ARMATURE