background image

The illustrations below depict  typical installations of the Model #2511 Lock on single-outswing doors. The lock 
assembly must be surface mounted to the underside of the frame header with the armature affixed to the inside 
face of the door as shown.

DynaLock Corp.

Electric Security Hardware

705 Emmett Street    P.O. Box 9470    Forestville, CT  06011-9470    Phone (860)582-4761    Fax (860)585-0338

MOUNTING INSTRUCTIONS

SERIES 2511 ELECTROMAGNETIC LOCK

FOR A SINGLE OUTSWING DOOR

PLEASE READ BEFORE INSTALLATION

.

Familiarize yourself with the door and frame conditions prior to installation.  The lock must rigidly mount to the 
underside of the frame header. The armature is designed to pivot slightly to compensate for reasonable 
misalignment.

Armature mounting hardware is supplied for a standard 1-3/4" thick door. For thicker doors order the following 
special armature hardware kits:

Part #300687 for 2" thick doors.
Part #300688 for 2-1/4" thick doors.

HANDLING

MAINTENANCE

The Electromagnetic lock and armature are 
ruggedly constructed and designed to provide 
years of trouble-free service.  Care must be taken 
during  installation and  use to keep the lock face 
and armature face free from dirt, rust, burrs, paint, 
or any other obstruction which may interfere with 
the lock and armature making good contact.

The lock  assembly and door armature have been 
plated for maximum corrosion resistance. To 
ensure peak performance clean the lock and 
armature faces with a mild detergent and a clean, 
soft cloth, then apply a light coat of WD40 to protect 
these surfaces.  This need only be done when dirt 
build-up is noticed.

page 1

GENERAL MOUNTING INFORMATION

LHRB DOOR

RHRB DOOR

LOCK

ASSEMBLY

ARMATURE

Summary of Contents for 2511 Series

Page 1: ...re mounting hardware is supplied for a standard 1 3 4 thick door For thicker doors order the following special armature hardware kits Part 300687 for 2 thick doors Part 300688 for 2 1 4 thick doors HANDLING MAINTENANCE The Electromagnetic lock and armature are ruggedly constructed and designed to provide years of trouble free service Care must be taken during installation and use to keep the lock ...

Page 2: ... an angle bracket or filler plate will be required for installation The lock will require a 1 3 4 wide header stop for a suitable mounting surface Determine the hand of the door LHRB or RHRB and look at the template edge for proper positioning of the template A Fold the template on the dotted line to form a 90 degree angle B With the door in the closed and latched positon place the template agains...

Page 3: ...ing holes and one 9 16 diameter wiring hole where shown Remove the Access and End Covers from the lock assembly see Exploded View page 4 Using the four 10 x 1 phillips flat head self tapping screws provided secure the lock assembly to the header Firmly tighten the screws with a 2 phillips head screw driver Locate the four anti tamper plugs and install over the mounting screw holes with a soft mall...

Page 4: ...t 1 1 8 Drill Bit 1 17 64 Drill Bit 1 1 4 Drill Bit 1 Hammer 1 Center Punch Pencil Tape 1 Mounting Instructions 1 Wiring Instructions 1 Electromagnetic Lock 1 Hardware Kit consisting of 4 10 x 1 Phillips Flat Head self tapping screws 4 Anti tamper Plugs 1 1 4 long Armature Spacer 1 1 8 thick Rubber Washer 1 1 16 thick Steel Washer 2 3 16 x 3 4 long Anti spin Pins 1 Template 1 Armature Bolt assembl...

Page 5: ...IPTION COMPONENT LOCATION COIL CONNECTION AND VOLTAGE SELECTION WHT BLK WHT BLK RED WHT GRN COIL CONNECTOR 4 PIN PLUG DYNASTAT CONNECTOR 3 PIN PLUG POWER INPUT 12 24 VDC VAC NO POLARITY VOLTAGE SELECTION SEE BELOW OPTIONAL DOOR STATUS DSM OPTIONAL DYNASTAT DYN REMOVEABLE JUMPERS VOLTAGE SELECTION SET FOR 12 VOLTS SET FOR 24 VOLTS REMOVEABLE COIL AND DYNASTAT CONNECTORS THE COIL AND DYNASTAT CONNEC...

Page 6: ...UTTON KEYSWITCH ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN CURRENT DRAW 2280 0 68A 12VDC 0 35A 24VDC 2500 0 50A 12VDC 0 25A 24VDC SHOWN PER COIL NC NO C DSM NC NO C DYN DYNALOCK CORP DOOR UNSECURE DOOR SECURE INPUT FROM INDICATOR POWER SOURCE DYNASTAT DYN OPTION LOCK STATUS BOND SENSOR DRY CONTACT RATING 0 25A 24VDC NOTE INDICATORS NOT INCLUDED DRY CONTACT RATING 0 25A 24VDC NOTE INDICATORS NOT...

Page 7: ...istor from the black wire Connect the LED to the DYN as shown below LED OPTION LOCK DYN TIME DELAY TD MODULE WIRING Optional Model 7080 inline time delay module provides adjustable time delayed relocking This is a field installed device and wired per the following wiring diagram REMOVE FOR 12VDC OPERATION LED Red Door Locked Green Door Unlocked TD Module Trim Pot Rotate trim pot clockwise to incre...

Page 8: ...C SHOWN PER COIL SURGE SUPPRESSION Built in COIL RESISTANCE 2280 34 1 Ohms 10 Black White Red Blue 2500 53 8 Ohms 10 Black Black White White GENERAL SPECIFICATIONS PLEASE DELIVER THIS MANUAL TO THE END USER UPON COMPLETION OF THE INSTALLATION FOR PRODUCT SUPPORT AND PARTS ORDERING INFORMATION CONTACT DynaLock Corp 705 Emmett Street Bristol CT 06010 Bus 877 DYNALOCK Toll Free USA 860 582 4761 Fax 8...