GLASS AND ALUMINUM
OR
HOLLOW METAL DOOR
SOLID CORE DOOR
REINFORCED DOOR
Drill an 11/32" diameter hole
through door. From sex nut
side only enlarge the 11/32"
hole to 21/32" diameter.
Drill an 11/32" diameter hole
through door. From sex nut
side only drill 1/2" diameter
hole to 1" depth.
Drill an 17/64" diameter hole
and tap for 5/16"-18 thread.
ARMATURE
STEEL WASHER
ARMATURE
SCREW
RUBBER
WASHER
ARMATURE
SPACER
D O O R
SPACER
SEX
NUT
21/32"
STEEL WASHER
ARMATURE
ARMATURE
SCREW
ARMATURE
SPACER
RUBBER
WASHER
1/2"
1"
STEEL WASHER
ARMATURE
ARMATURE
SCREW
ARMATURE
SPACER
RUBBER
WASHER
5/16"-18 THREAD
page 2
MOUNTING PREPARATION
SURVEY THE INSTALLATION
PREPARE THE FRAME FOR MOUNTING THE LOCK ASSEMBLY
PREPARE THE DOOR FOR ARMATURE MOUNTING
Inspect the door frame and determine if an angle bracket or filler plate will be required for installation. The lock will
require a 1-3/4" wide header stop for a suitable mounting surface.
Determine the hand of the door - LHRB or RHRB and look at the template edge for proper positioning of the template.
A. Fold the template on the dotted line to form a 90 degree angle.
B. With the door in the closed and latched positon, place the template against the header and door
with one edge of the template against the vertical lock jamb and tape in place.
C. Transfer all hole locations to both the door and header with a center punch.
D. Remove the template from the door.
From the three illustrations below, select the one that resembles your door type and follow the instructions for drilling
the armature mounting screw hole. Drill two (2) 1/4" dia. holes 9/16" deep at the anti-spin pin locations ( See
Template ).
1.
2.
3.
1 3/4"
MIN.
NORMAL MOUNTING
*FILLER PLATE REQUIRED
*ANGLE BRACKET REQUIRED
*These items are available from DynaLock