3101B MANUAL
02/08
MODEL 3101B
DELAY EGRESS SYSTEM
INSTALLATION INSTRUCTIONS
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
BASIC SET-UP
- Voltage Selection
Check that the voltage
selection jumper (J4) is
properly set to match your
input power. Note that all
locks are factory set for 24
volts.
- Fire Alarm Control
Check that the fire alarm
control jumper (J9) is
properly set to match your
fire panel input contacts.
If fire panel tie-in is not
required leave jumper at
factory setting (N.O.).
Remove the Electronics Cover to expose the circuit board assembly.
(Factory Setting)
(Factory Setting)
1.
2.
3.
- System Selector Switches
The selector switches (DS1) that control major system
functions are factory set to the OFF position for basic lock
operation. Switch 1 will be used during sensor adjustment
(page 8). Switches 2, 3 and 4 are only used for options
described on page 10.
4.
V
C
FA
(Factory Setting)
V
FA
C
SET FOR 24 VOLTS
REMOVEABLE JUMPERS
SET FOR 12 VOLTS
NO
C
NC
SET FOR
NORMALLY OPEN
INPUT
NO
C
NC
SET FOR
NORMALLY CLOSED
INPUT
1 2 3 4
ON
DS1
STANDARD SOFTWARE
VERSION 2K1.1