Leaders in Pipelin
e Survey Systems
C
C
C
-
-
-
S
S
S
C
C
C
A
A
A
N
N
N
2
2
2
0
0
0
1
1
1
0
0
0
SYSTEM MANUAL Version 6.03i
11
2.3. Signal Generator External Power
If the internal battery of the Signal Generator is too low to complete or carry out a survey
and there is no time to charge the Signal Generator, an external 12-18 volt battery (car
battery etc.) can be connected using the cable supplied (9-way socket terminated with red
and black crocodile clips). This will extend the usable time to the capacity of the external
battery.
The external power can be connected to the Signal Generator at any time, even during a
survey. The Signal Generator will recognise the presence of the external power and
automatically switch to that power source. If the external power source fails then the
Signal Generator will automatically switch back to internal batteries until either the internal
batteries are exhausted or the external power source is replaced.
During external power use the Signal Generator will not display the battery % and time
indication, instead EXTERNAL ON will be shown.
Note:
The external battery must be charged separately.
2.4. Charging the Detector Unit
There are two controls for the power supply to the Detector:
1. The
Main Power
isolator switch located in the battery compartment and normally left
ON
2. For normal operational use the Detector is switched ON and OFF by pressing the
button marked
I/O
on the Detector display panel / control keypad.
The Detector is powered by NiMH (Nickel-Metal Hydride) C cells (4500mAh). The battery
compartment is pictured below:
The Detector can be powered either
by re-chargeable NiMH batteries
OR
by alkaline batteries.
Only the NiMH batteries can be
charged using the following
procedure. Using the charger
with alkaline batteries installed in
the Detector will result in damage
to the unit.
Fig. 2.1 – Battery Compartment
If not already installed, unpack the six (6) NiMH batteries and put them to one side.
Remove the two battery covers using the battery removal tool. Ensure that the main
power switch in this compartment is OFF! Insert the batteries, NEGATIVE (-ve) end first,
three to each battery compartment, as shown in Fig. 2.2 below,
and re-fit the battery
covers. Use the battery removal tool to fit the covers but
do not over tighten or cross
thread the covers
.
Switch the
Main Power Isolator
to ON.
C Cells
4.5Ah NiMH
Main Power
Isolator (ON/OFF)