background image

6

Copyright © 2014 - 2022 Dynamic Projection Institute GmbH. All rights reserved. http://www.dynamicprojection.com

Weights and dimensions shown are approximate. Specifications and appearance are subject to change without notice. 

DMX OUT

DMX IN

ARTNET / LAN

RS 232

MENU

ENTER

AC OUT

AC IN

Mirror Head

Model: MHE01

DMX OUT

DMX IN

ARTNET / LAN

RS 232

MENU

ENTER

AC OUT

AC IN

Mirror Head

Model: MHE01

Art-Net™/HTTP 

Art-Net™

RS232

RS232

DMX

DMX Light Desk

Power

Power

Power

Power

Mirror Head control unit

Mirror Head control unit

Projector

Projector

Video

Video

This setup shows the combination of the Mirror Head 
and a Media Server (e.g. MDC-X) that is capable of 
Art-Net™/HTTP control, video playback and optional geo-
metry effects. For more information about controlling the 
Mirror Head see the „Using and operations“ section.

This setup shows how the Mirror Head can easily be 
integrated into DMX-Light Management (DMX512-XLR 
or Art-Net™) and Media-playback. For more information 
about controlling the Mirror Head see the „Using and 
operations“ section.

Media Server with Art-Net™ control and 

video playback

Media Player and DMX Light Table

optional

optional

Using and operations (DMX512 / Art-Net™ / HTTP)

To use the Mirror Head as intended, a DMX512/Art-Net™ controller is needed with at least 14 channels.

 

In order to control the Mirror Head at least a 14 channel DMX Master is required. 

DMX-512 controlled operation

  

1. 

Make sure the unit is turned off.

2. 

Connect the DMX XLR cable to the DMX-IN socket.

3. 

Connect the power-cord so the unit turns on.

4. 

Check the DMX settings in the control unit.

5. 

Start sending DMX commands and check if the system reacts.

Art-Net™ controlled operation

1. 

Make sure the unit is turned off.

2. 

Connect the power-cord so the unit turns on.

3. 

Check the DMX settings in the control unit.

4. 

Check the IP address settings in the control unit.

5. 

Connect the CAT cable to the control board.

6. 

Start sending Art-Net™ DMX commands and check if the system reacts.

RS232 projector control

  
The Mirror Head control unit offers the possibility to send some basic remote control commands to the projector using the RS232 interface.
1.  

Make sure the projector is turned on and accepts RS232 commands corresponding to the RS232 compatibility list in the appendix.

2.  

The commands are sent to the projector whenever a specific DMX value is sent on the specific DMX channel – see DMX fixture chart.

NOTE: It is maybe necessary to insert a 
DMX / XLR termination plug (with 120 
Ohm) in the last unit in the link in order to 
ensure proper transmission on the DMX 
data link – please ask your DMX operator.

NOTE: If you change the IP address of 
the unit you may have to replug the CAT 
cable in order to avoid ARP / IP caching of 
some intermediate switching equipment.

Media Player / Media Server

DPCC / Media Server

QIG - Version 2.8

Mirror Head Quick Installation Guide

For the full manual please visit 

https://www.dynamicprojection.com/mh-support/

Summary of Contents for MH08

Page 1: ...MH08 MH10 MH11 MH09 MH12 MH13 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 1 Surface coated mirror 2 Mirror Head control unit 3 Mirror Head module carrier QIG Version 2 8 Mirror Head Quick Installation Guide F...

Page 2: ...rtant that the fixture be returned in the original factory box The installation must always be secured with a secondary safety attachment e g an appropriate safety cable This secondary safety attachme...

Page 3: ...DMX OUT Through port 5 pin male and female XLR connectors At least 5 channels are required to control the unit Art Net connection RJ45 Art Net designed by and Copyright Artistic License Holdings Ltd...

Page 4: ...lly unpack the mirror do not tug or twist the attached cable 1 Rotate the Mirror in every possible position to make sure the cable doesn t block any movement Make sure the cable is mounted as shown on...

Page 5: ...them 1 If spacers are provided make sure to use them 2 Mount the adapter plate to the projector and then mount the Mirror Head to the projector and secure all screws do not fully tighten them 3 Adjust...

Page 6: ...equired DMX 512 controlled operation 1 Make sure the unit is turned off 2 Connect the DMX XLR cable to the DMX IN socket 3 Connect the power cord so the unit turns on 4 Check the DMX settings in the c...

Page 7: ...over again until you see DONE on the top of the screen Changes will then apply immediately to the network interface of the Mirror Head To force an ARP update disconnect the network cable for at least...

Page 8: ...irror motors LED Turns the drivers on 009 Motor and LED drivers off 50 58 Mirror motors LED Turns the drivers off 009 Lamp mode 1 130 138 RS232 projector Lamp power mode 1 009 Lamp mode 2 150 158 RS23...

Page 9: ...s 1 PAN Coase High Byte 0 255 In FX Mode PAN Position 5 Mirror Reset 255 Mirror calibration Reset system Blank when move ENABLED 128 190 7 FX Engine ENABLED 255 3 TILT Coase High Byte 0 255 In FX Mode...

Page 10: ...or Head support page https www dynamicprojection com mh support Channel Function Value Notes 10 LED Main Intensity 0 255 14 Acceleration default 0 12 LED Green Intensity 0 255 Damping amount 1 255 Val...