Sauna Shows Signs Of No Power 

Solution: 

There could be one of a few problems causing this. First, check to see if the cord from the 

power supply is plugged into the wall outlet. Also check your main circuit breaker to confirm that it has 
not tripped. Check the power supply on the roof of the sauna to make sure there are no signs of 
malfunctioning, such as a high temperature, burning odor, or strange sounds. Also, check to make 
sure none of the power cords are damaged. If the power supply is malfunctioning or power cords are 
damaged, then unplug the sauna immediately and contact the manufacturer. 

Solution: 

If your sauna is plugged in and you have no power at the control panel, then the power  

supply may need to be reset.  Go to the roof of the sauna and locate the power supply.  Press the   
RESET button to reset the power supply.  The RESET button is on the same side of the power supply   
as all the heater cord connections.   Attempt to turn the sauna on at the control panel.  Contact   
the manufacturer for any additional troubleshooting. 

Solution: 

There could be damage to the temperature sensor. If your sauna arrived with a spare 

temperature sensor, turn the control panel off and go to the roof of the sauna and locate the red and 
black wire near the air vent towards the rear of the sauna. After you have located the red and black 

wires labeled “TEMP SENSOR”, disconnect them. Connect the spare temperature sensor. For testing

 

purposes, insert the “TEMP SENSOR” (you just connected) down the vent on the roof so that it is now

 

inside the sauna. Then go to the control panel and press the power button. If the heat emitters now 
heat, then the temperature sensor was the cause of the problem. You may have to wait about five 
minutes to confirm if the heat emitters are generating heat. Remove the original temperature 
sensor from its hole and replace it with the spare one. 

Solution: 

Check the wiring harnesses coming from the power supply located on the roof of the sauna. 

Make sure the wiring harness labeled “CTRL” is connected to the power supply at one end and

 

connected to another wiring harness labeled “CTRL” at the other end. If this wiring harness is not

 

properly connected, then the sauna will show signs of having no power. 

4. 

CD Player Will Not Work (optional CD Players only available on limited models) 

Solution: 

Check to make sure the lock screws on top of the radio have been removed. The CD player 

will not work if the screws are not removed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DYN6215-01

Page 1: ... INDOOR USE ONLY DYN6215 01 120V 15 AMP DEDICATED CIRCUIT DYN6315 01 120V 20 AMP DEDICATED CIRCUIT Sauna Now you can enjoy the European secret for youthful vitality Carefully and thoroughly read this manual before using the sauna We recommend keeping this manual for regular review and future reference ...

Page 2: ...ured in microns near infrared 0 76 1 5 microns middle infrared 1 5 5 6 microns and far infrared 5 6 1000 microns Among these segments only far infrared penetrates organic substances such as the human body two to three inches so that the warming effect is very uniform ARE INFRARED RAYS SAFE Because infrared rays are part of sunlight they are not only safe but also highly beneficial to our bodies on...

Page 3: ...ternal organs without putting too much burden on the heart Our body reacts to the increased heating through the natural cooling process of perspiring Through the perspiration process acid and waste residue like toxins sodium alcohol nicotine cholesterol and the potentially carcinogenic heavy metals are removed from the cells especially zinc lead nickel cadmium etc The pores of our skin open and di...

Page 4: ...itted by your sauna are reported to offer a wide range of possible therapeutic benefits based on research completed over the last 25 years from all around the world These benefits are presented for reference purposes only and no implication of infrared saunas creating a cure for or treating any disease is implied nor should it be inferred If you have a health condition are taking prescription drug...

Page 5: ...dealer or manufacturer for troubleshooting and replacement parts 1 Product Introduction The infrared sauna room is composed of a wood cabin infrared heat emitters and a control system The wood cabin includes a FLOOR PANEL RIGHT SIDE WALL PANEL FRONT PANEL with GLASS DOOR LEFT SIDE WALL PANEL REAR WALL PANEL ROOF PANEL BENCH HEAT EMITTER PANEL and BENCH The infrared sauna comes with an interior con...

Page 6: ...6 PARTS DESCRIPTION DYN 6215 01 DYN 6315 01 ...

Page 7: ...signal cable group II Component Labeling POWER Power Cord HT1 HT2 HT3 HT4 Emitter heater power cords LIGHT Reading lamp connector ROOF LAMP Roof lamp connector not available on all models COLOR LAMP Color lamp connector not available on all models CTRL Control panel connector CD SIG For speakers temperature sensor etc connectors CD POWER CD radio power connector not available on all models FAN POW...

Page 8: ...ckets The Metal Guide Insert Brackets connect the FRONT WALL PANEL to the LEFT SIDE WALL PANEL and RIGHT SIDE WALL PANEL see Figure 3 Figure 3 C Wall Panels Will Be Placed Up Against The FLOOR PANEL The FLOOR HEAT EMITTER PANEL is located towards the front of the sauna room The arrows in the Figure 4 below are indicating where the wall panels will be placed up against the FLOOR PANEL Figure 4 ...

Page 9: ... identify the front of the FLOOR PANEL locate the FLOOR HEAT EMITTER PANEL with the wood grid cover Again this is going to be the front of the Sauna room once assembly is completed see Figure 5 Front of Sauna Room Figure 5 B Understanding The Wall The REAR WALL PANEL and the FRONT WALL PANEL with the GLASS DOOR are the largest of the wall panels The REAR WALL PANEL houses HEAT EMITTER PANELS The w...

Page 10: ... Choose a good location to assemble the sauna 1 The location must be dry leveled and away from any source of water 2 MAIN POWER cord must be easily accessible 3 Two adults are required for installation 4 Wood cabin installation order Floor Panel Front Wall Panel Right Side Wall Panel Left Side Wall Panel Rear Wall Panel Bench Heat Emitter Panel Bench Roof Panel Roof Cover 5 Tools Required Philips ...

Page 11: ...e The floor heater cord is located at the rear of the sauna room see Figure 8 Floor Heater Cord Figure 8 C Installing the FRONT WALL PANEL RIGHT SIDE WALL PANEL and LEFT SIDE WALL PANEL 1 Place the FRONT WALL PANEL up against the FLOOR PANEL Align the Metal Guide Insert Brackets on the FRONT WALL PANEL and the RIGHT SIDE WALL PANEL The RIGHT SIDE WALL PANEL will need to be lifted in order to lock ...

Page 12: ...ndicated in the pictures below see Figure 11 2 Plug in the BENCH HEAT EMITTER connector to the corresponding inlet located on the right side of the REAR WALL PANEL Also plug in the FLOOR HEAT EMITTER PANEL connector to the corresponding inlet on the left side of the REAR WALL PANEL 3 Install the BENCH at an angle as also seen in Figure 11 Connect the connection for the Accent LED lighting on the u...

Page 13: ...g to Figure 12 and Figure 13 the FRONT GLASS DOOR must sit between the 2 white washers The screws are inserted from the inside of the FRONT GLASS DOOR and screwed into the outer handle BE SURE NOT TO OVER TIGHTEN THE SCREWS OR YOU WILL SHATTER THE FRONT GLASS DOOR Next the inner door handle needs to be inserted over the screws Used the provided Hex Wrench to tighten the 4 hex screws see Figure 14 ...

Page 14: ...d REAR PANELS when you set the ROOF PANEL down onto the panels Feed the wires through the holes in the ROOF PANEL Feed the control cable up through the ROOF PANEL 3 Be careful not to force the ROOF PANEL into place Make sure that the wires are properly fed through the holes Furthermore make sure the ROOF PANEL sits snugly into the RIGHT SIDE WALL PANEL and RIGHT FRONT WALL PANEL Pull down on the R...

Page 15: ...Connect the CTRL plug from the power supply box to the CTRL plug from the control panel Then screw together see Figure 17 3 Connect the buzzer connection see Figure 18 not available on models with Bluetooth 4 On the top of the roof and at the rear connect the connection for the Accent LED lighting Figure 16 Figure 17 Figure 18 ...

Page 16: ...ing the TEMPERATURE SENSOR and Optional MAGAZINE RACK TOWEL RACK 1 Enter the sauna and remove the protective covering from the TEMPERATURE SENSOR Situate the TEMPERATURE SENSOR so that it is vertical and pointing downward see Figure 19 ...

Page 17: ... mount the Magazine Rack in the lower left hand side of the interior FRONT WALL PANEL in front of the glass window panel and the Towel Rack to the interior RIGHT SIDE WALL PANEL see Figure 20 and Figure 21 Figure 20 Figure 21 J Putting on the ROOF COVER 1 Place the ROOF COVER over the top of the sauna Be cautious when pulling the power cord through the hole in the roof cover Gently place the ROOF ...

Page 18: ...t the sauna room to the set temperature before entering Please keep in mind that you will increase the time it takes for the sauna room to reach the set temperature if you enter the sauna room before it has reached the set temperature 4 The set up time will count downward in minutes one by one The time will continue to count downward unless you interrupt the time by pressing the clock button and t...

Page 19: ...erted into the remote you are ready to operate the chromotherapy color therapy lighting system Press the button on the sauna control panel The white light will come on While pointing the remote at the ceiling light you can press any of the colors on the remote and that color will be displayed You can use the SHADE button on the remote to go through a sequence of colors If you want to turn the ligh...

Page 20: ...r model sauna has a floor heat emitter do not place any towels over the floor heat emitter Use the additional towel to wipe perspiration from your body from time to time 5 At the first sign of a cold or flu increasing your sauna sessions may be beneficial in boosting your immune system and decreasing the reproductive rate of viruses 6 To help relieve sore and tense muscles massage the affected are...

Page 21: ...ts on the interior of the sauna Only wipe down with a cloth and water 13 Do not stack or store any object on top or inside the sauna 14 If the power supply cord becomes damaged it must be replaced immediately by the manufacturer or its agent If you find the power cord is too hot or that the electrical equipment may be experiencing technical problems please contact the manufacturer or its agent imm...

Page 22: ...t the control panel displays the time and temperature then the temperature sensor may not be plugged in properly or it may be damaged Turn the control panel off and then go to the roof of the sauna and locate the red and black wires near the air vent towards the rear of the sauna After you have located the red and black wires labeled TEMP SENSOR disconnect them Connect the spare temperature sensor...

Page 23: ...th a spare temperature sensor turn the control panel off and go to the roof of the sauna and locate the red and black wire near the air vent towards the rear of the sauna After you have located the red and black wires labeled TEMP SENSOR disconnect them Connect the spare temperature sensor For testing purposes insert the TEMP SENSOR you just connected down the vent on the roof so that it is now in...

Page 24: ...sing or forgery of proof of purchase documents will be cause to VOID this limited warranty Products on which the serial number has been defaced or removed is not eligible for warranty service Warranty Limitations This warranty does not apply if the unit has been subject to negligence alteration modification misuse abuse repairs by non Golden Designs Inc authorized personnel inappropriate installat...

Page 25: ...sales receipt showing date of purchase as this will serve as proof of purchase Warranty will be VOID if the following warranty card is not mailed back within 60 days of purchase date along with proof of purchase Serial number S N is located on the sauna s front panel rear panel or on the carton DETACH HERE WARRANTY CARD All fields must be completed to validate the warranty Name Address City State ...

Reviews: