DYNAMIX 

FIBERMIX 2201/2401/2601-60 (REV.A)

 

Modular Ethernet Multiplexer 

User Manual

 

Dynamix Co., Ltd

 

Summary of Contents for FIBERMIX 2201

Page 1: ...DYNAMIX FIBERMIX 2201 2401 2601 60 REV A Modular Ethernet Multiplexer User Manual Dynamix Co Ltd ...

Page 2: ...that has precise elements please avoid violent shakes and impacts and do not disassemble or maintain the device yourself If it is required please do it under the guide of our technical staff following in the steps of anti static Please contact us if there is any need There must be grounding protection for the sake of safety do not disassemble the device yourself we regard it as you waiver your rig...

Page 3: ...he Front Panel 3 3 2 Dip switch 4 3 2 1 SW1 for Working Modes 4 3 2 2 Fault Pass Through Capability Explanation 5 3 2 3 E1 Remote Loop back Test 6 3 2 4 How to Implement Remote Network Management 6 4 Installation and Test 7 4 1 Inspect after Opening 7 4 2 Preparation before Installation 7 4 3 Installation 7 4 3 1 Connecting the Cables 7 4 3 2 Function Configuration 8 5 Troubleshooting 8 6 Appendix...

Page 4: ...iber optic cable and implement the line speed transmission of the Ethernet data FIBERMIX 2201 6CK FIBERMIX 2401 60 fll FIBERMIX 2201 2401 2601 6 series is featured by high integration and complete network management functions It can be installed into the Dynamix 3U high 16 slot chassis or desktop single slot chassis providing various network management functions 1 1 Main Features Low power consump...

Page 5: ...thernet interface increment 32kbps Implementation of SNMP capable of local and remote management 1 2 Part Number Explanation Example FiberMix 2 2 01 60 2 E1 channel 1 Ethernet interface Modular dual strand fiber optic L2 Ethernet switching capability Multi service Dynamix code 2 Parameters 2 1 E1 Interface Specification Bit rate Line code Interface impedance Electrical characteristic Transfer char...

Page 6: ...manual configurable Flow control IEEE802 3x and back pressure 2 3 Optical Interface Specification Bit rate Fiber connector Transmission distance 150Mbps Single strand fiber SC PC Single mode S1 0 25 km 2 4 Ambience Working temperature 0 45 C Relative humidity 90 25 C 3 How to use 3 1 Description of the Front Panel Power Supply Indicator PWR Power the green indicator will be lightened when the powe...

Page 7: ... the link is in normal condition It flashes when transmitting to receiving data 100M 100Mbps The green indicator will be lightened when working at the rate of 100Mbps E1 Interface RJ45 socket 120 Ohm balanced signal Pin 1 2 for output of first E1 channel pin 5 6 for input of first E1 channel Pin 3 4 for output of second E1 channel pin 7 8 for input of second E1 channel L R LOS1 Local Remote Lose S...

Page 8: ...ork management channel Forced remote network management Please configure as per the network topology Priority of configuration and command of network management software is higher than configuration of SW1 Configuration of SW1 is invalid when using network management software to configure Note The other dip switch SW2 is a 2 bit switch which shall be used by manufacturing people Users are not advi...

Page 9: ...rder to avoid misunderstanding users are advised to use it cautiously The factory default status is disabled 3 2 3 E1 Remote Loop back Test E1 remote loop back setup at local Ethernet Multiplexer Note when setup any kinds of loop back at the local Ethernet Multiplexer the remote loop back switch at remote Ethernet Multiplexer must be at default status When the module is at E1 remote loop back stat...

Page 10: ...anual Prepare all kinds of the cable Ensure that they are not short circuited Refer to Appendix A for cable making Ensure the pressure of power supply is in the tolerance range the chassis is well connected with the ground Prepare the BERT and optical power meter for test of line quality Place the equipment at stable and secure environment Pay attention to the requirements of the ambience 4 3 Inst...

Page 11: ...se try the following solutions If the problem still cannot be solved please contact distributors for technical support The following explanations and solutions to optical and E1 LOS alarms are for the local module If the alarms are at the remote site please solve them at remote site Power PWR indicator Green is not ON Answer Power supply fails Check whether the power supply is working properly LAL...

Page 12: ...to 120ohm balanced E1 interface of other equipment as per above table When user needs 75ohm unbalanced E1 interface twisted pair can be connected to E1 impedance converter RC909 1E1 is single E1 channel impedance converter of Dynamix Following is connecting figure of FIBERMIX 2201 60 FIBERMIX 2401 60 FIBERMIX 2601 60 and RC909 1E1 BNC BNC 9 FIBERMIX 2201 60 FIBERMIX 2401 60 FIBERMIX 2601 60 ...

Page 13: ...pment Note that the cable shall not be longer than 100 meters The cable can be either straight through or crossover The sequence of the RJ45 connector is as follows Pin Number 1 2 3 4 5 6 7 8 MDI Definition TX TX RX NotUsed NotUsed RX NotUsed NotUsed MDI X Definition RX RX TX NotUsed NotUsed TX NotUsed NotUsed ...