19
CA280 M280EN1
1
3
2
EVERY 250 HOURS OF OPERATION (Monthly)
Fig. 25 Drum
1. Ventilated screw
Drum cartridge
– Cleaning the ventilation screw
Clean the drum ventilation hole. The hole is required to
eliminate excess pressure inside the drum.
Unscrew the level plug (3) at the bottom of the cartridge
until the hole in the middle of the plug becomes visible.
Top off with oil through the filling plug (1), until oil begins
to run out from the level-plug hole. The level is correct
when it stops running.
Ensure that only MOBIL SHC 629 is used in
the cartridges.
Clean and refit the plugs. Repeat the procedure on the
opposite side.
Do not overfill with oil – risk for overheating.
Drum cartridge
Fig. 24 Drum cartridge
2. Drain plug
3. Level plug