background image

D016

-

047

-

1                     LeakVIEW User Guide                 Page 22 of 22

 

7.1 WARRANTY PERIOD

 

The LeakVIEW system has been carefully tested and inspected before shipment and is guaranteed to be 

free from defective materials and workmanship for a period of twelve months from date of purchase 

(invoice date).  

 

 

7.1.2 CONDITIONS OF WARRANTY

 

1.

 

This warranty is in addition to and does not affect any statutory rights of consumer purchasers. This 
warranty is valid worldwide on a "Return to supplier basis

”.

 

2.

 

This warranty covers breakdowns due to design or manufacturing faults; it does not apply to damage, 
however caused, wear and tear, neglect, unauthorised adjustment or repair, or any items of limited 
natural life such as the lid seal. Failure due to filling with water of incorrect temperature is also

 

excluded.

 

3.

 

In the event of a failure, please take the following action:

 

 

a] Refer to the Troubleshooting guide in Section 6 of this User guide and if possible correct the 

 

fault.

 

 

b] If the fault cannot be resolved, please contact the supplier at the address given on the cover of the 

 

in the CONTACT INFORMATION section of this guide.

 

 

4.

 

The warranty period applicable shall be 12 months from the date of delivery provided that:

 

 

 

a] Notice in writing of the defects complained of shall be given to the supplier (The Seller) upon their 

 

appearance, and:

 

 

 

b] Such defects shall have arisen from the Seller's faulty design, workmanship or materials.

 

 

 

c] The defective goods shall be returned to the Seller's premises at the Purchaser's expense if so 

 

requested by the Seller.

 

 

 

d] Any repaired or replaced goods shall be redelivered by the Seller free of charge to the original 

 

point of delivery but otherwise in accordance with and subject to the supplier

s Conditions of Sale.

 

 

 

e] Alternatively the Seller shall be entitled at its absolute discretion to refund the price of the defective 

 

goods in the event that such price shall already have been paid by the Purchaser to the Seller, or, if 

 

such price has not been so paid, to relieve the Purchaser of all obligation to pay the same by the

 

 

issue of a credit note in favour of the Purchaser in the amount of such price.

 

 

WARRANTY

 

This section describes:

 

• 

Routine maintenace

 

• 

User serviceable parts

 

• 

Emergency maintenance

 

• 

Cleaning 

 

SECTION 7: WARRANTY

 

Summary of Contents for LeakVIE M016

Page 1: ...LeakVIEW D016 047 1 USER GUIDE Seal Integrity Leak Detection Systems FOR USE WITH MODEL NUMBERS M016 011 Automatic IVG Size 1 M016 012 Automatic IVG Size 2 M016 LeakVIEW...

Page 2: ...r Manufactured by Cambridge Sensotec Ltd 29 Stephenson Road St Ives Cambridgeshire PE27 3WJ United Kingdom Dynascan is the leak detection brand of Cambridge Sensotec Ltd Tel 44 0 1480 462142 Email inf...

Page 3: ...t chamber Do not subject the test chamber to shock especially when under vacuum Do not allow the test chamber to come into contact with substances that can attack the acrylic Do not allow the weight o...

Page 4: ...Depth 310mm Base to clamp plate dimension M016 012 External dimensions Height 643mm Width 625mm Depth 500mm Internal Test Chamber dimensions Height 330mm 260mm Width 500mm Depth 330mm Pressure Plate...

Page 5: ...E EMISSION PACK TESTING DEVICE CONTROLLER Model Designation s M016 020 Serial Number ____________ Conforms to the principle safety objectives of the European Directive 2006 95 EC by application of the...

Page 6: ...nt leakage is observed or for burst testing For a standard bubble emission test the following sequence takes place 1 The packs are placed in the chamber and the lid is closed This causes the pressure...

Page 7: ...UTION indicates where a failure to observe an instruction or precaution could result in equipment damage or undesirable operation A NOTE indicates important information that helps the operator make be...

Page 8: ...e chamber to bare down on the drain tap fitted to the base The test chamber is also heavy this may require two people to lift it Ensure body parts are kept clear of the base of the chamber when it is...

Page 9: ...1 POWER SUPPLY FUSE There is a single fuse fitted inside the fuse holder within the IEC mains connector on the rear panel Replace with the same specification fuse The LeakVIEW fuse type and rating is...

Page 10: ...ee Ensure the air supply is connected to the correct port Provision must be made to iso late the air supply in an emergency 3 5 TEST CHAMBER CONNECTIONS The Vacuum and Sense tubing from the test contr...

Page 11: ...ge the tread by over tightening A right angle fitting is included for optional use if required Figure 3 5 indicates the suggested orientation of the tap with right angle fitting A suitable length of h...

Page 12: ...ses the evacuation rate The key may be removed to lock the system in the selected mode START BUTTON Moving to this sector holds the vacuum at the desired level and deactivates the vacuum generator RES...

Page 13: ...o a level that covers the top of the pressure plate when the pack has expanded but is within 3cm of the chamber opening The water level may need to be adjusted to accommodate a wide range of pack volu...

Page 14: ...800 mbars Do not exceed a vacuum level of 800mbars 3 The total Test Time in seconds This is the time the vacuum is held constant 4 An Evacuation Timeout in seconds This is the time allowed for the vac...

Page 15: ...in the Run position The Run Mode screen will be displayed Fig 5 4 3 Open the test chamber lid 4 Place the pack into the water 5 Close the lid Take care not to displace the water over the edge of the...

Page 16: ...d the system will restore the vacuum level by pulse evacuating the test chamber End of test 3 At the end of the test time period the system will release the vacuum in the test chamber by allowing air...

Page 17: ...turing process are satisfactory and that the pack can withstand the stress Subjecting the pack to a simulated altitude of 9000Ft for ground or 16 000Ft for pressurised air transportation should be con...

Page 18: ...d to aid observation 6 As the vacuum is increasing observe the pack for any failure 7 When the required vacuum level has been attained move the control lever to the HOLD position Refer to table 5 3 3...

Page 19: ...D016 047 1 LeakVIEW User Guide Page 19 of 22 5 2 3 ALTITUDE SIMULATION TESTING ALTITUDE TO VACUUM RELATIONSHIP LEAKVIEW OPERATION Table 5 1 The relationship of vacuum to altitude...

Page 20: ...Refill the chamber with water that is of the same temperature or less than the ambient chamber temperature 6 4 2 LID SEAL REPLACEMENT Should the lid become damage this should be replace by using the...

Page 21: ...oose if the drain tap has been rotated the PTFE seal may leak If this is the case the tap should be removed and the seal remade Target vacuum cannot be attained Evacuation Time out indicated Lid not f...

Page 22: ...ess given on the cover of the in the CONTACT INFORMATION section of this guide 4 The warranty period applicable shall be 12 months from the date of delivery provided that a Notice in writing of the de...

Reviews: