38
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HYDRAULIC SCREW COMPRESSORS
INSTALLATION
4.3.2. CONNECTION TO THE AIR SUPPLY SYSTEM
Compressor can be connected to the air supply system with a proper fitting and
cut-off valve (options).
Picture 31: Air supply system connection
The inner diameter of pipe / hose used for compressor’s connection should be at
least equal to AP-port to keep the pressure drop minimal.
The length of a pipeline, with the pipe of same diameter as AP-port, can be 50 m
as maximum. For longer lines use larger diameter.
Max
50
m
ø
AP
ø = ø
AP
ø < ø
AP
PSI
BAR
MIN
MAX
PRESSURE
PSI
BAR
MIN
MAX
PRESSURE
Picture 32: Air supply line hose diameter and length