41
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HYDRAULIC SCREW COMPRESSORS
OPERATION
ATTENTION !
The compressor must not be operated in conditions where toxic or
flammable vapors could be aspirated.
The compressor is not allowed to use to compress toxic, corrosive,
explosive or noxious gases.
Compressed air delivered by a HKR-compressor must not be used as breathing air,
even if purified and filtered.
Picture 35: Compressed air must not be used as breathing air
HKR-compressor is designed to compress athmospheric air only and must not be
used with any other gas.
If the compressor is connected to the distribution network or consumer with a
flexible hose, ensure that the hose is of proper diameter and pressure class.
Damaged or worn hose should be replaced immediately.
5.3. AIR AND OIL TEMPERATURES
Normal operating within ambient temperature range -5 ºC... + 45 ºC.
0
+45
-5
Picture 36: Normal operating ambient temperature