MAINTENANCE
6.1. MAINTENANCE INTERVALS
ATTENTION!
All maintenance must be complied as they are scheduled in this manual.
The following table provides maintenance schedule for DYNASET HKR screw
compressor.
CHECK POINTS
Daily
Monthly or
every 100 h
Every 6
months or
1000 h
Every 12
months or
2500 h
Check oil level
x
Check system for leaks
x
Change air intake filter
o
x
Change the air-oil separating element
x
Change oil and oil filter
x
o = Check / change if necessary
x = Change
NOTE
!
All installation and service of must be performed by experienced
personnel only.
6.2. HYDRAULIC FLUIDS
Wide range of standard hydraulic fluids can be used with DYNASET hydraulic
equipment. Depending on the operating temperature, following mineral hydraulic
oils are recommended:
Mineral hydraulic oil
Operation temperature up to
ISO VG 32S
60 °C
ISO VG 46S
70 °C
ISO VG 68S
80 °C
NOTE!
Recommended oil viscosity is between 10 to 35 cSt when operating at
normal operating temperature.
Synthetic and bio-oils can also be used if their viscosity characteristics and
lubricating efficiency are similar to the mineral oils.