2. Lubricate the seal of the new oil filter cartridge with clean oil or grease. Fill the
cartridge with the same oil as in the HKR screw compressor.
OIL
OIL
3. Insert the new oil filter cartridge onto the multiblock and tighten by hand. Use
of a tool is prohibited.
4. Start the compressor and close air supply line. Allow compressor run for 3
minutes. Check the compressor and the system for leaks when the system is
running.