65
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HYDRAULIC SCREW COMPRESSORS
MAINTENANCE
FAILURE
REASON
CORRECTIVE ACTION
Insufficient discharge.
Intake filter element soiled. Replace filter element.
Oil level too low.
Check the oil level. Fill if
necessary.
Incorrect operation of
intake control valve.
Check control valve anv control
valve flap, clean the bearing and
guides. chek stroke, replace if
necessary.
Leaks in system
Check. Seal if necessary.
FAILURE
REASON
CORRECTIVE ACTION
Oil escapes during stop.
Sealing surfaces in control
valve is damaged, spring in
control valve is broken.
Check and replace parts.
FAILURE
REASON
CORRECTIVE ACTION
Abnormal noise during
operation.
Insufficient lubrication,
loose parts, damage
to hydraulic drive kit,
bearings or shaft, etc.
Check. If necesasry, replace parts.
Summary of Contents for HKR 1300
Page 2: ......
Page 75: ...DYNASET OY all rights reserved...