35
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HYDRAULIC SCREW COMPRESSORS
INSTALLATION
4.2. INSTALLING DYNASET HYDRAULIC PRODUCT
4.2.1. PLACING DYNASET HYDRAULIC PRODUCT
Place DYNASET hydraulic product where there is an easy access to the unit. Ensure
proper ventilation.
Picture 25: Placing the HKR compressor
NOTE!
When positioning the HKR compressor note the maximum inclinations and
ensure that required oil cooling capacity of hydraulic system is sufficient.
READ CHAPTER “10. TECHNICAL SPECIFICATIONS” for specific cooling
capcities.
4.2.2. INSTALLING DYNASET VALVES
Installation instructions can be found in DYNASET LSV or DYNASET PV SAE
installation manual.
4.2.3. CONNECTING HYDRAULIC HOSES
Connect pressure- (P) and return (T) lines of a hydraulic system to the corresponding
hydraulic ports of the DYNASET unit.
Summary of Contents for HKR 1300
Page 2: ......
Page 75: ...DYNASET OY all rights reserved...