OPERATION
5.2. STARTING THE COMPRESSOR
ATTENTION!
When starting the compressor, ensure that the unit is decompressed.
When the engine of base machine is running and hydraulic flow is available, the
HKR compressor can be started by opening the hydraulic control valve.
Air out
Picture 34: Starting the compressor
Compressor starts to produce usable compressed air when hydraulic flow achieves
the functional minimum rate, which is approx. a half of the nominal value.
The nominal discharge is achieved when the compressor is rotated by hydraulic
flow adequate to the nominal rotation speed.
When compressor is running, oil circulation is proper when gray air-oil-mixture
mist can be seen from the oil return line sight glass.
NOTE!
Before using the compressor in cold conditions READ CHAPTER “5.6. Cold
ATTENTION !
Compressor’s maximum hydraulic pressure must not be exceeded in any
circumstances.
Hydraulic flow and pressure values marked on the compressor’s type plate are
maximum and should not be exceeded in any circumstances. Exceeding the
maximum hydraulic flow causes compressor to overspeed and may damage it.
READ CHAPTER “10. TECHNICAL SPECIFICATIONS” for correct pressure and flow
rates.