Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
18
HIGH PRESSURE DUST SUPPRESSION
OPERATING PRINCIPLES
3.3.2. SINGLE WATER CIRCUIT (SWC)
Single Water Circuit comes with one type of nozzles. The output water flow and
pressure is controlled with hydraulic valve kit. Hydraulic valve provides two
separate hydraulic flows to the HPW-pump. Lower hydraulic flow to the continuous
dust suppression and higher hydraulic flow to the high power dust suppression.
Picture 6: Single Water Circuit installation diagram
1. Basic nozzles
2. Hydraulic valve
Summary of Contents for HPW DUST 130 DOUBLE DUST