OPERATION
5. OPERATION
After having ensured the proper mechanical and hydraulic installation of the
HPW-DUST system it is ready for use.
5.1. BEFORE OPERATING THE HPW-DUST SYSTEM
Picture 16: Before operating the HPW-DUST system
1. Ensure that the water filter is clean and in place.
2. Fill the water tank with clean water or ensure water line connection from a tap.
NOTE!
Maximum feed pressure to the HPW-pump is 16 bar
5.2. STARTING AND STOPPING THE HPW-DUST SYSTEM
HPW-DUST system is started and stopped by activating/deactivating hydraulic
flow to the HPW-pump. On/off switch is typically installed into cabin’s aux panel.
5.3. HIGH POWER DUST SUPPRESSION
In double dust system made with dual water circuit, the high power dust suppres-
sion mode is activated with push-button installed into boom joystic. Pressing the
button once activates the and pressing the button again disables the high power
mode.
In double dust system made with single water circuit, the basic and high power
dust suppression is controlled by 3-pole switch which is typically installed into
cabin’s aux panel.
The high power dust suppression is intended for discontinuous use, but if the
water pipeline is available, the high power mode can be used on continuous basis
when necessary.