Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
33
HIGH PRESSURE DUST SUPPRESSION
MAINTENANCE
6.4. CLEAN WATER FILTER
Check and clean water filter weekly.
Picture 18: Clean water filter
Remove the water filter. Wash the water filter under clean water to remove all soil
and dirt from the filter. Renew the filter if necessary.
6.5. TROUBLESHOOTING
Performing the maintenance tasks requires a qualified hydraulic mechanic.
Please, contact DYNASET authorized workshop or dealer for more maintenance
information.
FAILURE
REASON
CORRECTIVE ACTION
HPW-DUST system does not
work.
Hydraulic flow not
sufficient or no hydraulic
flow at all.
Enable or adjust the hydraulic
flow.
Hydraulic pressure too low. Adjust the hydraulic pressure.
Hydraulic flow reversed.
Check and reconnect hydraulic
hoses. Pressure hose should be
connected to P-port and return
hose to T-port.
Summary of Contents for HPW DUST 130 DOUBLE DUST
Page 2: ......