background image

3 flashing dots are displayed.

A problem has been detected.

Do not enter the water! Check and open water valves.

Clean filter if necessary. Check water level. Add water

if needed.

Shut power off and power your spa up again to reset the

system.

Call your dealer or service supplier if problem persists.

Water temperature is flashing.

Water temperature in the spa has reached 112˚F (44˚C).

Do not enter the water! Allow water to cool down. The

system will reset automatically when water temperature

reaches 109˚F (43˚C).

Call your dealer or service supplier if problem persists.

The display is flashing.

A power failure has occurred.

Press any key to reset the system, then reprogram all

desired parameters.

TROUBLESHOOTING

Pumps have started up for one 

minute on several occasions and

"Filter Cycle" indicator is flashing.

Not a bug but a feature!

Our

 Smart Winter Mode 

protects your spa from the

cold by automatically turning pumps on for one minute

several times a day to prevent water from freezing in pipes.

N.B.: After a power failure, the filter cycle duration 

will return to its default value (2 hours). In this case, 

the first filter cycle will start one minute after power 

has been restored.

Press and hold 

Filter 

key

until the display shows "

xx

",

representing the currently

set filter cycle duration in

hours.

When the desired setting is dis-

played, press 

Filter 

key to confirm. 

A filter cycle starts immediately.
Note: Light needs to be turned 

off before the filter cycle can be

programmed.

Use 

Up

 or 

Down

 arrow keys

to change setting.

  0 = no filtration

12 = continuous filtration

• E

Q U

I P P

E D W I

T H G E C K O ' S E X C L

U S I V

E •

Smart

Winter

Mode

 

TM

9919-100578-B

The filter cycle is suspended if the water temperature 

raises more than 2˚F (1˚C) above Set Point or if spa

is in use (pumps started manually). The "Filter" icon 

will flash (on 0.5 second, off 0.5 second, on 0.5 sec-

ond, off 1.5 second).

Automatic water heater start:

When water temperature is 1˚F (0.5˚C) lower than  

the Set Point, the heater will automatically turn on until 

water temperature reaches Set Point plus 1˚F (0.5˚C).
 

The "Heater" indicator lights up when the heater is  

 

on. It flashes when there is a request for more    

 

heat but the heater has not yet started.

N.B.: If your system is configured in Low Current Mode,

the heater will not start if a pump is on at high speed.

Press 

Econo

 key to switch from Normal mode 

to Economy mode. In Economy mode, system 

maintains temperature at the desired Set Point 

during filter cycles only. Set Point is 20˚F (11˚C)

below the Normal mode Set Point for the rest 

of the time. In Economy mode, the display will 

toggle between the current water temperature 

and the "Econ" message.

Economy mode:

PROGRAMMING FILTER CYCLE DURATION

The system automatically performs two filter cycles per day, at 12-hour intervals. 

During a filter cycle: Pump 2 runs for one minute, then Pump 1 runs at low speed for the programmed number of hours
The "Filter Cycle" indicator lights up when the filter cycle is on. To set filter cycle duration:

Reviews: