background image

7

• E

Q U

I P P

E D W I

T H G E C K O ' S E X C L

U S I V

E •

Smart

Winter

Mode

  TM

9919-100417-B

Lock

icon

Temperature

unit

Programming Mode

icon

Filter Cycle

icon

Heater

icon

Economy Mode

icon

Up & Down

arrows

Step

Programming

Sequence

Step 1
Step 2
Step 3
Step 4

Time of day
Filter cycle start time
Filter cycle duration
Filter cycle frequency

Summary of control panel parameters

FSxx    

Filter cycle start time

Fdxx    

Filter cycle duration

FFxx    

Filter cycle frequency

ESxx    

Economy mode start time

Edxx    

Economy mode duration

Tu X    

Temperature unit

LocX    

Control pad lockout

Step 5

Economy mode start time

Step 6

Economy mode duration

Step 7

Storing settings in memory & returning to Normal mode

This function allows you to prevent unauthorized parameter 

setting of the unit. This feature is especially helpful when young 

children have access to the keypad.

There are two modes you can choose from: 

Full

 lock or 

Partial

 

lock. 

Full

 lock means that all keypad functions are locked. 

Partial

 

lock means that the basic functions of the spa will remain accessi-

ble (pumps, blower and light), but it will be impossible to change 

the temperature Set Point, to override the Economy mode or 

to enter the Programming mode. 

When control pad is locked, the "Lock" icon will be displayed.

Locking your digital control pad:

 

1- Press and hold 

Pump 1

 key for

 

     5 seconds.

 

2- The display will show 

LocP

, with "P"

 

     representing 

Partial

 lock.

 

3- Release the key and the keypad will be

 

     in 

Partial

 lock mode. Keep key pressed

 

     down for 5 more seconds if you want

 

     to be in 

Full

 lock mode. The "LocF"

 

     message will then be displayed.

When control pad is locked, all automatic functions of the 

system run as usual. If a key is pressed down, a "LocP" or "LocF" 

message will be displayed for 1 second. To unlock the keypad, 

simply press and hold 

Pump 1 

key again for 5 seconds.

Digital control pad lockout

LocP

LocF

Inverted display

Press and hold 

Pump 2 

for 5 seconds to invert the display. Note 

that the ˚F or ˚C icon is not displayed in reverse mode. Follow 

the same procedure to return to default mode. If a power-up 

occurs, the display always returns to default mode.

Economy mode

Press 

Econo

 key to switch from Normal mode to Economy 

mode. To save energy, the Economy mode Set Point is 20˚F 

(11˚C) below the Normal mode Set Point.

 

The "Economy Mode" icon lights up when Economy

 

mode is on.

There are 3 available Economy operating modes:

noEc: 

No Economy mode

Ec 1: 

Economy mode always on

Ec 2: 

Economy mode on during a programmed

 

number of hours (

see Steps 5 & 6*

)

Selecting the desired Economy mode:

 

1- Press and hold 

Econo

 key for

 

more than 2 seconds.

 

2- The display will show the current 

 

  mode (noEc, Ec 1 or Ec 2).

 

3- Keep key pressed down until the 

 

  desired mode is displayed.

After 5 seconds, the new setting will be programmed.

Ec 1

noEc

Step 1- Time of day

Setting the time:

 

1- Enter Programming mode by holding 

 

     

Prog.

 key pressed down for 2 seconds. 

 

2- The display will show the current setting. 

 

3- Use 

Up

 and 

Down

 arrows to change 

 

     setting.

11:43 

pm

10:25 

am

The system automatically performs two filter cycles per day, at

12-hour intervals. During the filter cycle, Pumps 1 & 2 and the

blower will run the first minute, then Pump 3 will run for one

minute. Pump 1 will then run at low speed for a programmed

number of hours. The "Filter Cycle" icon lights up when a filter

cycle is on.

To program a filter cycle, you must enter: 1) the time you want

the cycle to start and 2) the duration of the cycle. If no filtering is

required, the duration should be set to "0". For continuous

filtering, the filter cycle duration should be set to "12:00".

Setting filter cycle start time:

 

1- Press 

Prog. 

key a second time.

 

2- The display will show 

FSxx

, with "xx"

 

     representing the starting hour.

 

3- Use 

Up

 and 

Down

 arrows to change

 

     setting.

Setting filter cycle duration:

 

1- Press 

Prog.

 key a third time.

 

2- The display will show 

Fdxx

, with "xx"

 

     representing the duration in hours.

 

3- Use 

Up

 and 

Down

 arrows to change

 

     setting.

Steps 2 & 3- Filter cycle start time & duration

FS12

FS01

Fd12

Fd00

Setting filter cycle frequency:

 

1- Press 

Prog.

 key a fourth time.

 

2- The display will show 

FFxx

, with "xx"

 

     representing the frequency per day.

 

3- Use 

Up

 and 

Down

 arrows to change

 

     setting.

Step 4- Filter cycle frequency

FF04

FF01

Step 7- Storing settings in memory

Press 

Prog.

 key a seventh time to store settings in the system's 

non-volatile memory and to return to Normal mode.

Steps 5 & 6- Economy mode start time & duration*

Setting Economy mode start time:

 

1- Press 

Prog. 

key a fifth time.

 

2- The display will show 

ESxx

, with "xx"

 

     representing the starting hour.

 

3- Use 

Up

 and 

Down

 arrows to change

 

     setting.

Setting Economy mode duration:

 

1- Press 

Prog.

 key a sixth time.

 

2- The display will show 

Edxx

, with "xx"

 

     representing the duration in hours.

 

3- Use 

Up

 and 

Down

 arrows to change

 

     setting.

ES08

ES10

Ed04

Ed01

Reviews: