Spa Operator’s Guide
Sec1:13
IMPORTANT SAFETY
INSTRUCTIONS
READ AND FOLLOW ALL
INSTRUCTIONS
DANGER-RISK OF ELECTRIC SHOCK. CONT.
Do at least two lugs marked “Bonding Lugs” are provided on the external
surface or on the inside of the supply terminal box or compartment. To
reduce the risk of electric shock, connect the local common bonding grid
in the area of the spa to these terminals with an insulated or bare copper
conductor not smaller than No. 4 AWG.
All field-installed metal components such as rails, ladders, drains or other
similar hardware with 3m of the spa shall be bonded to the equipment
grounding bus with copper conductors not smaller then No. 4 AWG.
CAUTION -
Test the ground fault circuit interrupter before each use
of the spa.
CAUTION -
Read the instruction manual.
CAUTION -
Adequate drainage must be provided if the equipment
is to be installed in a pit, or equivalent.
WARNING -
Water temperature in excess of 100.4°f (38°c) may be
injurious to your health.
WARNING -
Disconnect the electric power before servicing.
17)
18)