Spa Operator’s Guide
Sec1:29
SET-UP & DELIVERY GUIDELINES
Electrical Requirements
• (NA) Your 220 Volt spa pack will require a double pole 60 amp
dedicated GFCI, ground fault circuit breaker. (refer to page 25)
• (EU) Your 230 Volt spa pack will require a dedicated
breaker. (refer to page 20-21)
Caution:
Connect only to a circuit protected by a class A ground fault
circuit interrupter.
• Extension cords are not to be used in conjunction with operation of
the spa. Low voltage damage could result, which is not covered by
warranty.
• If you have any doubts, have your electrical system checked by a
licensed electrician.
• Use copper conductors only.
It is the customer’s responsibility to acquire necessary permits and
to arrange for installation and hook up of the electrical power by a
licensed electrician.
NOTE!
3” (7.62 cm) Concrete pad
Disconnect must be located in
sight and no closer than 5 feet
(1.52m) from inside walls of the
spa.
Service panel
Disconnect switch
WARNING
TAG
Warning tag
Electrical requirements