Water temperature in the spa has reached 112˚F (44˚C).

Do not enter the water! Allow water to cool down. The
system will reset automatically when water temperature
reaches 109˚F (43˚C).

Call your dealer or service supplier if problem persists.

HOW TO PROGRAM THE FILTER CYCLE DURATION

The system will automatically perform two filtration cycles per day, 12 hours apart. During a filter cycle, the pump runs at low 
speed for a predetermined number of hours. The ozonator is also activated. The "Filter" indicator light will be on when a filter 
cycle is in progress.

To set the filter cycle duration: 

TROUBLESHOOTING

Press and hold the 

Light 

key for

5 seconds. The display will show
the currently set filter cycle duration
in hours.

Use the 

Up 

or 

Down 

arrow key

to change the setting.
0 = no filtration
12 = continuous filtration

When the desired setting is 
displayed, press the 

Light 

key 

to confirm. A filter cycle will start
immediately.

Water temperature is flashing.

The display is flashing.

9919-100099-B

1.800.78.GECKO

• E

Q U

I P P

E D W

I T H G E C K O ' S E X C L

U S I V

E •

Smart

Winter

Mode

 

TM

GECKO

An irregularly flashing "Filter" indicator light indicates that
the system has stopped filtering after 3 hours because the
water temperature exceeds the set point by more than
2˚F (1˚C). If the temperature cools down to 1˚F (0.5˚C)
above set point before the scheduled end of the cycle,
filtering will resume for the remaining of the programmed
duration.

Note: After a power failure, the filter cycle duration 
will return to its default value (6 hours). In this case, the 
first filter cycle will start 12 hours after power has been 
restored.

Pumps have started up for one 
minute on several occasions and
"Filter Cycle" indicator is flashing.

3 flashing dots are displayed.

Not a bug but a feature!

Our

 Smart Winter Mode 

protects your spa from the

cold by automatically turning pumps on for one minute
several times a day to prevent water from freezing in pipes.

A problem has been detected.

Do not enter the water! Check and open water valves.
Clean filter if necessary. Check water level. Add water
if necessary.

Shut power off and power your spa up again to reset the
system.

Call your dealer or service supplier if problem persists.

A power failure has occurred. Press any key to reset the
system, then reprogram all desired parameters.

Reviews: