Problem:

Possible cause:

Correction:

Bulb does not illuminate 

and fan does not spin.

1. No electrical power.

1. Check plug and receptacle and fuse or circuit breaker.

2.  Check to make sure power is switched to the  

“on” position.

Bulb illuminates, but fan 

does not spin.

1. Shorted fan.

1.  UNPLUG UNIT: Examine fan to see that it is free from 

foreign material, dirt or build-up of dead insects.  

Clean unit as in “CLEANING” section.

Fan spins, but bulb does 

not illuminate.

1.  Bulb not seated 

properly.

2. Burnt out bulb.

1.  Check all sockets for proper bulb seating and alignment.

2.  Replace bulb if needed following instructions under  

“Replacing Bulb”.

LIMITED WARRANTY

 warranties to the original purchaser that this product is free from defective materials and 

workmanship. This warranty is limited to remedy any defective part for a period of one year from date of 

original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply 

to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in 

force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada 

and Mexico. In no case shall 

 be liable for any accidental, punitive, consequential, or any other 

damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some 

states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion 

may not apply to you. This warranty gives you specific legal rights, and you may also have other rights 

that vary from state to state.

PARTS & ACCESSORIES AVAILABLE

PART  

DESCRIPTION

41050 

7-Watt Replacement Fluorescent Bulb (1 piece)

41051 

Fan Blade Replacement

41052

 

Fan Blade and DC Motor Ultra-Long Life Replacement

41053 

Retaining Cage

41061

 

Large Capacity Net (to be used instead of the Retaining Cage, suitable for extra large catch performance)

Dynamic Solutions Worldwide, LLC
12247 W. Fairview Ave.
Milwaukee, WI 53226
Phone: 414-431-2819
Fax: 414-453-9975
Toll free: 1-877-403-TRAP (8727)
Or visit us online at www.dynatrap.com
EPA Est. No.  088119-CHN-001 
EPA Est. No.  087837-WI-001

©2012 DSW-LLC

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 

WARNING

, When using electric appliances, basic precautions should always be followed, including the following:

– To disconnect, turn all controls to the off (“O”) position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
–  This appliance is provided with double insulation. Use only identical replacement parts.
– Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).  
See instructions for Servicing of Double-Insulated Appliances.

INSTRUCTIONS FOR DOUBLE-INSULATED, CORD-CONNECTED APPLIANCES:

In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided  
on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated  
appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel.  
Replacement parts for a double-insulated appliance must be identical to those parts in the appliance.

IMPORTANT SAFETY INSTRUCTIONS

Please read these instructions before using the DYNATRAP

®

 Insect Trap and keep for future reference.

 1.   Always turn unit off and disconnect plug before servicing, cleaning, or changing bulb.
 2.  Do not position the unit near heat, gas, oil or other flammable materials.
 3.  Place product out of reach from children.
 4.    Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or  

damaged, or if it has been dropped into water.

 5.   This product is equipped with 2-conductor cord and 2-prong polarized plug as a safety feature. This plug will fit in a 

polarized outlet only one way. If the plug does not fully fit in the outlet, then reverse the plug. If it still does not fit,  
then contact a qualified electrician. To reduce the risk of electrical shock, only plug into a properly installed outlet.  
Do not attempt to defeat this safety feature.

 6.  Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
 7.  Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
 8.   Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
 9.  Do not touch fan while in motion.
 10.   Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from heat, 

oil, or sharp edges.

 11.   Extension cords used with this product must be marked with suffix letters “W-A” and with a tag stating “Suitable for Use 

with Outdoor Appliances”.

 12.   Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.

Thank you for purchasing the
DYNATRAP

®

 flying insect trap!

TROUBLESHOOTING

INSTALLATION & OPERATING INSTRUCTIONS

 

1.  Unpack unit. Save carton for off-season storage (if needed).

 2.   Assemble stand: Pull the cord tight through the poll stand. Turn base on its side and insert bottom 

threaded plastic piece into base, connecting to the threaded plastic cap. Twist threaded plastic cap  
clockwise to tighten. Complete installation by aligning upper and lower support tube and inserting the 
bar sections. (For more detailed instructions, please refer to the assembly guide.) 

 3.   Plug cord into an outlet or UL listed extension cord as described in “IMPORTANT SAFETY INSTRUCTIONS”.
 4.   Hold the Power switch on the side of the revolving rotation door. Twist the unit to the “Power ON”  

position. When you hear a “click”, the machine is turned on. 

 5.  For best catch results leave unit on at all times, except when cleaning or servicing.
 6.   Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing light sources. 

Intended for household use only.

 7.  It is recommended to place the unit at least 10 to 20 feet away from where people will be sitting.
 8.  This unit is all weather resistant – designed for outdoor use including rainy conditions.

CLEANING

Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
 1.  Be sure to clean the unit once per week
 2.   To clean, hold the switch on the revolving rotation door and turn it to the “POWER OFF” position. After hearing the “click”, 

the machine is turned off. Unplug the unit.

 3.   For weekly cleaning, remove the screw securing the retaining cage and then twist the cage clockwise. Remove any buildup from the inside 

of the retaining cage and fan with a brush (included).

 4.   For major cleaning, remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan 

housing away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process has 
been completed, align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of 
the lighting unit. 

 5.  When replacing the retaining cage – DO NOT press/push against the screen windows.

REPLACING BULB

The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal UV 
effectiveness. Even though the bulb’s light may be visible to you, its ability to attract insects diminishes over time.
 1.  Turn power switch to “off” position. UNPLUG UNIT, and allow bulb to cool before replacing. 
 2.  Remove retaining cage, and turn unit upside down.
 3.   Remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan housing away from 

the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process has been completed, 
untighten the screw securing the base of the light bulb to the light housing. Slide the metal bracket to the side. Cover the bulb with a 
cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull the bulb from 
the socket.

 4.   Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal plate over the base of the bulb 

and tighten the retaining screw.

 5.   Align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of the lighting unit. 
 6.  Replace the retaining cage at the bottom of the unit.
Replacement fluorescent bulbs can be found at your local retailer or can be ordered directly from 

 by visiting  

www.dynatrap.com

HOW THE DYNATRAP

®

 INSECT TRAP WORKS

Flying insects are attracted to the unit by UV light and CO

2

 that is 

generated by the photo-catalysis between the UV lamps and spe-
cial TiO

2

 coating. The fan then pulls the insects into the screened 

base, trapping them until they dehydrate and die. The base can be  
removed, allowing the contents to be periodically emptied into 
the trash. The see-through screen shows the insects trapped in the  
compartment, alerting you when the net needs to be emptied.

UV BULB

TiO

2

 COATED  

SURFACE

RETAINING 

CAGE

FAN

OWNER’S MANUAL

FLYING INSECT TRAP

MODEL: DT1250