Problem:
Possible cause:
Correction:
Bulb does not illuminate
and fan does not spin.
1. No electrical power.
1. Check plug and receptacle and fuse or circuit breaker.
2. Check to make sure power is switched to the
“on” position.
Bulb illuminates, but fan
does not spin.
1. Shorted fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
foreign material, dirt or build-up of dead insects.
Clean unit as in “CLEANING” section.
Fan spins, but bulb does
not illuminate.
1. Bulb not seated
properly.
2. Burnt out bulb.
1. Check all sockets for proper bulb seating and alignment.
2. Replace bulb if needed following instructions under
“Replacing Bulb”.
LIMITED WARRANTY
warranties to the original purchaser that this product is free from defective materials and
workmanship. This warranty is limited to remedy any defective part for a period of one year from date of
original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply
to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in
force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada
and Mexico. In no case shall
be liable for any accidental, punitive, consequential, or any other
damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some
states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
that vary from state to state.
PARTS & ACCESSORIES AVAILABLE
PART
DESCRIPTION
41050
7-Watt Replacement Fluorescent Bulb (1 piece)
41051
Fan Blade Replacement
41052
Fan Blade and DC Motor Ultra-Long Life Replacement
41053
Retaining Cage
41061
Large Capacity Net (to be used instead of the Retaining Cage, suitable for extra large catch performance)
Dynamic Solutions Worldwide, LLC
12247 W. Fairview Ave.
Milwaukee, WI 53226
Phone: 414-431-2819
Fax: 414-453-9975
Toll free: 1-877-403-TRAP (8727)
Or visit us online at www.dynatrap.com
EPA Est. No. 088119-CHN-001
EPA Est. No. 087837-WI-001
©2012 DSW-LLC
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING
, When using electric appliances, basic precautions should always be followed, including the following:
– To disconnect, turn all controls to the off (“O”) position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
– Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
See instructions for Servicing of Double-Insulated Appliances.
INSTRUCTIONS FOR DOUBLE-INSULATED, CORD-CONNECTED APPLIANCES:
In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided
on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated
appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel.
Replacement parts for a double-insulated appliance must be identical to those parts in the appliance.
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the DYNATRAP
®
Insect Trap and keep for future reference.
1. Always turn unit off and disconnect plug before servicing, cleaning, or changing bulb.
2. Do not position the unit near heat, gas, oil or other flammable materials.
3. Place product out of reach from children.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or if it has been dropped into water.
5. This product is equipped with 2-conductor cord and 2-prong polarized plug as a safety feature. This plug will fit in a
polarized outlet only one way. If the plug does not fully fit in the outlet, then reverse the plug. If it still does not fit,
then contact a qualified electrician. To reduce the risk of electrical shock, only plug into a properly installed outlet.
Do not attempt to defeat this safety feature.
6. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
8. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
9. Do not touch fan while in motion.
10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from heat,
oil, or sharp edges.
11. Extension cords used with this product must be marked with suffix letters “W-A” and with a tag stating “Suitable for Use
with Outdoor Appliances”.
12. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
Thank you for purchasing the
DYNATRAP
®
flying insect trap!
TROUBLESHOOTING
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. Assemble stand: Pull the cord tight through the poll stand. Turn base on its side and insert bottom
threaded plastic piece into base, connecting to the threaded plastic cap. Twist threaded plastic cap
clockwise to tighten. Complete installation by aligning upper and lower support tube and inserting the
bar sections. (For more detailed instructions, please refer to the assembly guide.)
3. Plug cord into an outlet or UL listed extension cord as described in “IMPORTANT SAFETY INSTRUCTIONS”.
4. Hold the Power switch on the side of the revolving rotation door. Twist the unit to the “Power ON”
position. When you hear a “click”, the machine is turned on.
5. For best catch results leave unit on at all times, except when cleaning or servicing.
6. Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing light sources.
Intended for household use only.
7. It is recommended to place the unit at least 10 to 20 feet away from where people will be sitting.
8. This unit is all weather resistant – designed for outdoor use including rainy conditions.
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Be sure to clean the unit once per week
2. To clean, hold the switch on the revolving rotation door and turn it to the “POWER OFF” position. After hearing the “click”,
the machine is turned off. Unplug the unit.
3. For weekly cleaning, remove the screw securing the retaining cage and then twist the cage clockwise. Remove any buildup from the inside
of the retaining cage and fan with a brush (included).
4. For major cleaning, remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan
housing away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process has
been completed, align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of
the lighting unit.
5. When replacing the retaining cage – DO NOT press/push against the screen windows.
REPLACING BULB
The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal UV
effectiveness. Even though the bulb’s light may be visible to you, its ability to attract insects diminishes over time.
1. Turn power switch to “off” position. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove retaining cage, and turn unit upside down.
3. Remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan housing away from
the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process has been completed,
untighten the screw securing the base of the light bulb to the light housing. Slide the metal bracket to the side. Cover the bulb with a
cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull the bulb from
the socket.
4. Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal plate over the base of the bulb
and tighten the retaining screw.
5. Align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of the lighting unit.
6. Replace the retaining cage at the bottom of the unit.
Replacement fluorescent bulbs can be found at your local retailer or can be ordered directly from
by visiting
www.dynatrap.com
HOW THE DYNATRAP
®
INSECT TRAP WORKS
Flying insects are attracted to the unit by UV light and CO
2
that is
generated by the photo-catalysis between the UV lamps and spe-
cial TiO
2
coating. The fan then pulls the insects into the screened
base, trapping them until they dehydrate and die. The base can be
removed, allowing the contents to be periodically emptied into
the trash. The see-through screen shows the insects trapped in the
compartment, alerting you when the net needs to be emptied.
UV BULB
TiO
2
COATED
SURFACE
RETAINING
CAGE
FAN
OWNER’S MANUAL
FLYING INSECT TRAP
MODEL: DT1250