Page | 108
SkyView
HDX System
General Maintenance Manual, Revision F
NOTE:
Because the pitot and AoA plumbing lines have not been annealed, they work-
harden rapidly when manipulated. Make gentle bends, and only bend any given
section once.
3. Remove screws that secure AoA Probe to mounting mast. Keep screws for re-installation.
4. To remove from airplane, gently and firmly pull AoA Probe in a downward motion and pull
plumbing lines through mast.
8.19.3
Installation
1. Insert the AoA plumbing lines through the mast and into the airplane.
2. With a firm upward motion insert the probe into the mast.
3. Secure AoA probe to mast using same screws (see
if
screws need to be replaced).
4. Remove pneumatic tube plug.
5. Connect the pneumatic tubing to the AoA Probe plumbing line.
6. If the original equipment is re-installed in the same location, no calibration is required.
Performance of the system should be verified in flight. If new equipment is installed or
installed in a new location perform the Zero Pressure IAS/AoA Calibration (see Section
) and AoA Calibration (see Section
).
8.20
Autopilot Servos
Autopilot servo removal and installation instructions are specific to airplane model.
8.20.1
Location
For specific location, see the
SkyView HDX System
Equipment Installation Record
document
associated with the airplane.
8.20.2
Removal
See the
Autopilot Servo Installation Manual
associated with your airplane.
8.20.3
Installation
See the
Autopilot Servo Installation Manual
associated with your airplane.