4. Select a file and press LOAD. NOTE: Press REMOVE to delete old files from USB flash
drive.
5. Once loaded, go to SETUP MENU > LOCAL DISPLAY SETUP > INSTALLED
DATABASES to verify databases and charts are current (see
).
Figure 81: Installed Databases
9.4
SkyView HDX System Backup Battery Test
The Backup Battery for the SkyView HDX system must be tested once every 12 months to
ensure it is operational and meets the nominal 45-minute expected backup operation period.
Each SkyView HDX Display requires a Backup Battery, and each Backup Battery must be tested.
The Backup Battery must be fully charged prior to beginning the test. To test the battery,
complete the following steps:
1. Remove power from SkyView HDX Display by turning off Master Switch.
2. On SkyView HDX Display, during the 30-second power off countdown, press TEST BAT
button (see
Figure 82: TEST BAT Button
3. The BATTERY TEST screen will appear, displaying the status of the test. If the Backup
Battery can power the system for at least 45 minutes, the battery passes the test.
4. After test completes, the SkyView HDX Display will automatically power itself off.
To see the results of the test, go to SETUP MENU > LOCAL DISPLAY SETUP > BATTERY
BACKUP (SV-BAT-320) STATUS>TEST RESULTS. Make sure the TEST RESULT says
PASS. If PASS is displayed, battery is good. If FAIL is displayed, battery needs to be
replaced (see Section