SkyView
HDX System
General Maintenance Manual, Revision F
Page | 97
1. Apply thread sealant to pipe threads.
2. Thread sensor into boss and tighten to prevent gas leak.
3. Connect wiring harness connector to sensor.
4. Conduct an operation test to confirm correct operation and that there are no gas leaks.
8.12.13 Amps Sensor
The SV-EMS-220 utilizes an ammeter shunt to sense amps. Refer to the airplane or engine
manufacturer’s maintenance manuals for detailed location information.
If your aircraft did not originally come equipped with this sensor, refer to the
Equipment
Installation Record
document to see where the sensor is located on your airplane.
Removal:
To remove the Amp sensor, follow the removal instructions in the airplane or engine
manufacturer’s maintenance manuals, or complete the following steps:
1. Shut down airplane power.
2. Temporarily label wires connected to sensor to ensure correct orientation when
reconnecting wires.
3. Remove screws that secure large input wire cable terminals to sensor.
4. Remove screws that secure large output wire cable terminals to sensor.
5. Remove screws that secure small signal wire connected to input side of sensor.
6. Remove screws that secure small signal wire connected to output side of sensor.
7. Remove screws that secure sensor to airframe, and then remove sensor.
Installation:
To install the Amp sensor, follow the installation instructions in the airplane or engine
manufacturer
’s maintenance manuals, or complete the following steps:
1. Locate sensor and install screws that secure sensor to airframe (see
if screws need to be replaced).
2. Install screws that secure small signal wire connected to input side of sensor.
3. Install screws that secure small signal wire connected to output side of sensor.
4. Install screws that secure large input wire cable terminals to sensor.
5. Install screws that secure large output wire cable terminals to sensor.
6. Restore power to airplane.
8.12.14 Voltmeter Sensor
The SV-EMS-220 utilizes the existing wire connected to the main battery bus supplying your
airplane’s original volt indicator to provide the voltage indication in the SkyView HDX Display.
This wire connects to the EMS module wiring harness as depicted in the
103488-000 - WIRING
DIAGRAM, TYPICAL HDX DUAL DISPLAY
document.
8.12.15 Tachometer Sensor
The SV-EMS-220 utilizes the existing P-lead wires connecting the left and right magnetos to the
magneto control switch mounted to the airplane instrument panel to provide left and right
magneto pulse signals to the Skyview HDX Display. The left and right tachometer sensing wires