8.18.2
Removal
1. Shut down airplane power and disconnect the battery.
2. Remove D9 and D25 connectors from ARINC 429 Connection Module.
3. Remove screws that secure ARINC 429 Connection Module to avionics tray, and then
remove it. Keep screws for re-installation.
8.18.3
Installation
1. Install ARINC 429 Connection Module unit in same location using same screws (see
if screws need to be replaced).
2. Connect D9 and D25 connectors to ARINC 429 Connection Module.
3. Restore power to airplane.
4. Turn SkyView system
ON
.
5. On the SkyView HDX Display, verify that the Navigator can be selected for the HSI
for Troubleshooting information.)
8.19
AoA Probe
This section provides removal and installation procedures for the Angle of Attack (AoA) probe.
8.19.1
Location
Typically, the AoA probe is located underneath the left or right wing. For specific location, see
the
Airplane-specific Install Record
document associated with the airplane.
Figure 72: AoA Probe (Typical Installation Shown)
8.19.2
Removal
1. Shut down airplane power and disconnect the battery.
2. Disconnect the pneumatic tubing from the AoA Probe plumbing line. Plug the tube end.