SkyView SE
Pilot’s User Guide
- Revision B
5-1
5.
EMS Operation
This chapter describes SkyView SE EMS functionality and a few of the advanced ways to use it
to monitor the health and operation of your engine.
This chapter references the Engine Page. This page should have been configured
during SkyView SE installation. Reference the SkyView / SkyView SE System
Installation Guide for more information.
Engine Page Layout
The three Engine Pages (100%, 50%, and 20%) should have been configured during
installation. The appearance of the 20% and 50% Engine Pages are not scaled down
versions of the 100% Engine Page. They are unique layouts and must be laid out
individually.
The Engine Page as shown in Figure 35 displays important engine parameters acquired using an
SV-EMS-220 module, its sensors, and other advanced engine monitoring features.
Figure 35
–
50% Engine Page
Its appearance is determined using the Screen Layout Editor under the EMS Setup Menu and
should have been configured during installation. All EMS widgets that have assignable color
ranges, can include: red, yellow, green, black, blue, white, purple, cyan, and orange, for