Messages and Alerts
SkyView SE
Pilot’s User Guide
- Revision B
9-9
Spoken Alert (if
configured)
Message Displayed
in Message
Window
Notification
Area Alert
(severity)
Description
“Message”
CHECK BARO
SETTING
The current BARO setting and the
nearest METAR-based altimeter
setting are more than .1 inHg
apart. Or the aircraft has
descended below FL180 and the
BARO should be reset.
“Message”
BATTERY TEST
FAILED
A full backup battery test was
performed, and it failed. See the
Installation Guide for further
troubleshooting information.
“Message”
BATTERY TEST
NEEDED
A year or more has passed since
the last successful backup battery
test, or the last three SkyView SE
shutdowns were abnormal.
“Message”
SOFTWARE
MISMATCH
SkyView SE components are not
all running the same software
version
“Message”
TAIL # MISMATCH
Tail numbers differ between
SkyView SE displays
–
settings will
not properly synchronize
“Message”
XPNDR NOT IN ALT
MODE
The aircraft is in flight and the
Transponder is not in Alt Mode
“Message”
CPU TEMP HIGH
The display internal temperature
is significantly higher than the
normal operating temperature.
“Message”
BACKUP BATT LOW
CHARGE
The backup battery connected to
this display is not charged.
“Message”
SYSTEM EVENT n
SkyView SE has detected a
possible problem with software or
hardware. Please fill out form at
convenient.
“Message”
XPNDR WARNING
MESSAGE
The transponder has detected a
problem and notified SkyView SE.
See the SETUP MENU for the
specific problem.
“Gees” (repeats)
None
n/a
The G meter is in the yellow
caution range
“Over Gees” (repeats)
None
n/a
The G meter is in the red warning
range