SV-D700, SV-D1000 and SV-D1000T Operation
SkyView Classic Pilot’s User Guide –
Revision Z
5-13
All Circuits
•
RESET button: Press this button to reset any circuit that has a fault condition that
the VP-X will allow to be reset. This button will be grayed out and unavailable if the
circuit is not in a fault condition.
Flaps and Trim Circuit Controls
•
UP and DOWN buttons:
o
For Elevator Trim: Moves the elevator trim up or down as described in the VP-X
documentation. This button can be held down for continuous trim movement.
o
For Flaps: Moves flaps up or down as described in the VP-X documentation.
Depending on the VP-X configuration, a single quick press of the UP or DOWN
button may move the flaps to a preconfigured angle or notch of flaps. Or, it may
only move the flaps momentarily. This button can be held down for continuous
trim movement.
•
LEFT and RIGHT buttons:
o
For Roll Trim: Moves the roll trim left or right as described in the VP-X
documentation. This button can be held down for continuous trim movement.
Power Circuits
•
ON and OFF buttons: Press these buttons to turn a circuit or device on or off on
demand. These buttons are not available if the circuit is in a fault condition. ON and
OFF override the physical VP-X switch for the circuit (if configured) until the relevant
VP-X physical switch is toggled.