perating The Boiler

Start Up / Shut Off The Boiler

Turn the ON/OFF switch to ‘ ON ’ position. LCD display will turn 
ON and, Power-on sequence will be monitored for several 
seconds. After the power-on sequence is completed successfully, 
LCD display shows actual Central Heating (CH) flow 
temperature.
                                                                                                                                

Fig 2

Status LEDs CH / DHW when OFF indicate “stand-by” 
mode, no demand for DHW or CH. 

CH (Central Heating) Mode

      

Fig  3 

By adjusting the CH control knob, summer or winter mode 
can be selected.

a) Summer mode

Rotate the CH control knob to the ‘ 

 ’ position. In this 

summer mode, CH mode is off, only DHW can be supplied. 

b) Winter mode

Rotate the CH control knob to the ‘ 

 ’ position. 

In the winter mode, your appliance satisfies central heating                              

Fig 4

and also domestic hot water                                                                                

Fig 5

Adjust the CH water flow temperature between 30 

o

C and 

80 

o

C with the CH control knob. The setpoint value 

appears on the LCD display when the left dot is flashing. 
After 10 seconds, actual CH water temperature will appear 
instead of the setpoint and left dot disappears. The boiler 
will modulate to the desired temperature. If  a hot water 
tap is opened, DHW mode will interrupt the CH mode (hot 
water priority) until DHW requirement ceases . 

       

In case of failed ignition, automatic ignition sequence is 
repeated 3 times. If all ignition attempts fail, “ No flame 
signal” lockout occurs. The burner LED will turn 

RED

 and 

error code “ 

4

 

” will flash on the LCD display to indicate 

this error condition. Press the reset push-button to turn 
back the normal operation again. If the lockout 
condition continues after pressing the reset push-button, 
continue to page 6 for , Fault finding. 

1

Fig 7

Fig 6

Summary of Contents for Confeo Premix

Page 1: ...Confeo Premix CP 24 HM GC Appliance No 47 144 03 24 kW Central Heating Output 26 kW Domestic Hot Water Output Confeo Premix CP 30 HM GC Appliance No 47 144 04 30 kW Central Heating Output 31 kW Domestic Hot Water Output USER OPERATING INSTRUCTIONS Veruk23308 ...

Page 2: ...affect your statutory rights under UK or IE consumer law The Benchmark Scheme ECA Heating is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hot water...

Page 3: ...Display Panel Blue Backlit LCD Display and 4 Yellow Status LED s Central Heating CH Temperature Control Knob Domestic Hot Water DHW Temperature Control Knob Pressure Push button Reset Push button Burner LED Control Panel Cover 2 4 5 7 3 1 Fig 1 6 ...

Page 4: ...g 4 and also domestic hot water Fig 5 Adjust the CH water flow temperature between 30 o C and 80 o C with the CH control knob The setpoint value appears on the LCD display when the left dot is flashing After 10 seconds actual CH water temperature will appear instead of the setpoint and left dot disappears The boiler will modulate to the desired temperature If a hot water tap is opened DHW mode wil...

Page 5: ...eat function Economy Mode Comfort Mode maintains the DHW plate heat exchanger in a preheated condition dependent upon usage patterns to ensure fast delivery of hot water Preheat cycle typically last less than 1 minute In economy Mode DHW preheat function is cancelled To select Comfort Mode turn the DHW temperature control knob fully clockwise and then back to the desired DHW temperature setting wi...

Page 6: ...ontrol panel and monitor pressure increase 6 Fill when cold to approximately 1 bar cold range 0 6 1 5 bar once reached turn off filling loop taps If water goes over pressure reduce by draining a small amount from heating system drain offs 7 Remove filling loop copper pipe A refit plug ends and reset DHW CH control knobs to required temperatures Frost Protection The bolier will go on and off automa...

Page 7: ...od flow from tap or try different tap Make sure DHW knob is not set to DHW cancellation mode No Central Heating LED display on Turn CH control knob to maximum Check external time clock and room thermostat are calling for heat set to maximum No Central Heating DHW indication on Check if taps are running leaking No CH or DHW Display shows 40 Low System Pressure Press pressure button pressure must be...

Reviews: