10.2- Using the Device
10.2.1- Switching off the Device
You can switch off the boiler by holding down the ON/ OFF button for 3 seconds.
LCD light will be OFF after 1 minute.
Anti-freeze function remains active.
11-CONTROL PANEL
11.1- Functions of Buttons
The control panel consists of the relevant elements as shown in figure 1
7
below.
Figure 17
Control Panel
Position Selection Button
The position can be changed by pressing the position selection button once to change between the winter mode
and the summer mode. If the button is pressed for 3 seconds, the device will switches into "standby" position. It
will suffice to press the button once to get the device in operation position.
Reset Button
Main functions:
•
Exit from lockout error (EXX)
•
ECO mode activation
•
Comfort mode activation
When your device fails, the error code will start flashing on the display. There are 2 types of errors, lockout (EXX)
and blocking (FXX) error. When a lockout error condition occurs (EXX), the error must first be corrected so that
the error code can be removed from the LCD screen. After pressing the "Reset" key once, the device can switch