7.3- Distances for Placement of Flues
Figure 8
POSITION
DISTANCE (cm)
POSITION
DISTANCE (cm)
A-Below a windows
60
G- Next to vertical or horizontal pipe
60
B- Below an air vent
60
H- Below the distance grille from the outside
of the building
30
C- Below rain channel
30
I- Distance from the inner corner of the
building
100
D- Under the balcony
30
L- From the ground or from the floor
180
E- Next to a window
40
M- Vertical distance of two flue outlets
150
F- Next to an air grill
60
N- Horizontal distance of two flue outlets
100
Table 3
14