background image

PROCEDURE 5

: - 

 
If the water is very murky!  

Unit OFF!

 

 
1.

 

Set 

BYPASS Valves 

to BYPASS the eClear system. 

2.

 

Adjust pH to 7.4ppm – 7.6ppm 

3.

 

Switch PUMP OFF

4.

 

You will need a surface level flocculent (

Alum Powder or liquid

)  

5.

 

Sprinkle the floc all over the surface of the pool and leave over night. 

6.

 

SWITCH PUMP ON.

 

Vacuum all debris to waste and not through the filter. 

7.

 

Repeat above points 2 to 4 if still not clear. 

8.

 

When clear go to number 

3

 of 

PROCEDURE 1

.

 

 
 

MARBLE AND VINYL - NEW POOLS - Unit OFF! 

 

PROCEDURE 6

: -

 

 
New Marble pools need to be de-gassed and plaster/cement dust removed. Vinyl pools 
need to be de-gassed. The procedure is the same. The process is best over a 3 week 
period. This is to the benefit of the owner! 
 
1.

 

Back-Wash and Rinse filters thoroughly. 

2.

 

Adjust pH to 6.8ppm – 7.2ppm (

Always Pre-Mix 

pH correction chemicals in water 

and enter into skimmer with eClear on

 Bypass and switched OFF

)  

3.

 

Use house-hold bleach at 4 Litres per 50m3 and per week. 

4.

 

Add a Non-Metallic Algaecide through the skimmer at 1 Litre per 40m3 each week for 
3 weeks. 

5.

 

Add 1 Action Cube or Non Metallic filter flocculent in to the pump Pre-Filter. Replace 
when used. 

6.

 

Back-Wash and rinse filters after 24 Hours then once each week. 

7.

 

After 3 weeks, go to number 

3

 of 

PROCEDURE 1.

 

 

NOTE

: If you continue to use Chlorine then the procedure will take another week. So 4 

weeks of degassing and plaster dust removal. 
 

IMPORTANT

: - If a Marble pool. After the degassing and cleaning period, remove the filter 

top, and remove any debris. Mix well the top sand. If necessary, replace the sand. Back-wash 
for 5 minutes and then rinse for 3 minutes. 

 

F.A.Q. 

 
Algae Problems

: - 

Copper residual below 0.5ppm   Raise this to 0.7ppm but first shock       
treat with ACTIVE OXYGEN and Non metal Algaecide. 
 

 

 

 

 

 

 

Good Maintenance

: -  It is a good idea to clean your electrodes once each year. Remove 

Cell and mix 1 part acid to 2 parts water. 
Pass the liquid several times through the Cells in a bucket. 
 

Summary of Contents for MK7/CF1-150

Page 1: ...m here onwards 5 If the above is adhered to you will have a trouble free pool that will last for years and years This will also make your initial start up very easy REQUIRED FOR WATER SET UP BEFOR SWITCH ON 1 5 10 litres of Active Oxygen Depending on pool size 2 5 10 litres of non copper based algaecide Depending on pool size 3 Non metallic floc cubes optional FOR YOUR REFERENCE DIAGRAM ATTACHED C...

Page 2: ...the UV Optional Then also switch on the UV Figure 9 8 Check the conductivity mA meter Figure 1 Raise to 200mA for the MK7 CF1 75 For the MK7 CF1 150 raise to 250mA This is achieved by setting the pool size switch Figure 2 to A or B then turn the potentiometer knob slowly clockwise Figure 3 This will also depend on the conductivity of your water If the dosing meter indicates a very high output e g ...

Page 3: ...e Calcium NOTE It could take as long as 2 weeks to finally obtain clear consistent water REMEDY This is a short term and initial set up problem meaning that you did not confirm your pool shell and filtration system with us prior to installation for full advice If your tiled pool has sound grouting the filter sand is new and the pipes have been cleaned then your pool is being detoxified The natural...

Page 4: ... on Bypass and switched OFF 3 Use house hold bleach at 4 Litres per 50m3 and per week 4 Add a Non Metallic Algaecide through the skimmer at 1 Litre per 40m3 each week for 3 weeks 5 Add 1 Action Cube or Non Metallic filter flocculent in to the pump Pre Filter Replace when used 6 Back Wash and rinse filters after 24 Hours then once each week 7 After 3 weeks go to number 3 of PROCEDURE 1 NOTE If you ...

Reviews: