User Manual for EE08 Humidity / Temperature Probe

For outdoor operation the use of an appropriate radiation shield is of paramount importance. The 

EE08 is compatible with rotational symmetric radiation shields which protect it against rain, snow and 

overheating caused by direct sunlight (available as accessory HA010502, suitable for type E8 and 

HA010506, suitable for type E11).

3.2  Dimensions

EE08 with connector (

Type E11) 

EE08-MxE11xxx

EE08 with cable (

Type E8)  

EE08-MxE8xxx

M12x1

61 

(2.4)

73 

(2.87)

25 

(1)

12 

(0.47)

connector M12x1 
(8 poles)

M16x1.5

61 

(2.4)

71 

(2.8)

83

 (3.27)

12 

(0.47)

Fig. 1 

Dimensions of EE08 in mm (inch)

5

1.5

20

Ø5

(Ø0.2)

20

(0.8)

122

 (4.8)

Ø105 

(4.1)

174 

(6.9)

44 

(1.7)

94

 (3.7)

22

(0.9)

1.5

(0.06)

Fig. 2 

Dimensions of optional radiation shields HA010502 and HA010506 in mm (inch)

3.3  Electrical Connection

EE08 with cable:

EE08-M1xE8xxx

T active

EE08-M6xE8xxx

T passive, 4 wire

GND

pink

pink

T-out

grey

not connected (grey)

RH-out

yellow

yellow

SCL

}

 

E2-

interface

green

green

SDA

brown

brown

+UB

red

red

T-passive

not connected (white)

white, black

T-passive

not connected (blue)

blue, violet

Summary of Contents for EE08

Page 1: ...BA_EE08 v1 3 Modification rights reserved EE08 High Precision Miniature Humidity and Temperature Probe User Manual...

Page 2: ...es and can radiate high frequency energy If it is not installed and used in accordance with the operating instructions it may cause electromagnetic interference to radio communications However there i...

Page 3: ...ons 4 1 2 2 Intended Use 4 1 2 3 Mounting Start up and Operation 5 1 3 Environmental Aspects 5 2 Scope of Supply 5 3 Product Description 5 3 1 General 5 3 2 Dimensions 6 3 3 Electrical Connection 6 4...

Page 4: ...ing the filter cap make sure not to touch the sensing elements The device must be operated with the filter cap on at all times For sensor cleaning please see Cleaning Instructions at www epluse com EE...

Page 5: ...into operation Do not install or start up a device supposed to be faulty Make sure that such devices are not accidentally used by marking them clearly as faulty A faulty device may only be investigate...

Page 6: ...xxx EE08 with cable Type E8 EE08 MxE8xxx M12x1 61 2 4 73 2 87 25 1 12 0 47 connector M12x1 8 poles M16x1 5 61 2 4 71 2 8 83 3 27 12 0 47 Fig 1 Dimensions of EE08 in mm inch 5 1 5 20 5 0 2 20 0 8 122 4...

Page 7: ...e The use in dirty dusty polluted environment might arise the need for cleaning the sensing head and replacing the filter cap In such a case please see the Cleaning Instructions at www epluse com EE08...

Page 8: ...Accuracy at nominal voltage1 Outputs Analogue 0 1 V 0 2 5 V 0 5 V 0 10 V 0 2mA IL 0 2 mA Digital interface E2 interface2 General Supply voltage for output 0 1 V 0 2 5 V V1 4 5 15 V DC V2 7 30 V DC for...

Page 9: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Reviews: